Note: Ingredients listed on restricted chemical lists
EC/CAS
107-75-5
Name of the chemical
7-Hydroxycitronellal
Concentration
N/A
EC/CAS
106-22-9
Name of the chemical
Citronellol/ (±) 3,7-Dimethyl-6-octen-1-ol (3R)-3,7-dimethyloct-6-en-1-ol (3S)-3,7-dimethyloct-6-en-1-ol
Concentration
N/A
EC/CAS
6259-76-3
Name of the chemical
Hexyl 2-hydroxybenzoate
Concentration
N/A
EC/CAS
2705-87-5
Name of the chemical
Allyl cyclohexylpropionate; 2-Propenyl 3-Cyclohexanepropanoate
Concentration
N/A
EC/CAS
118-58-1
Name of the chemical
2-hydroxybenzoic acid phenylmethyl ester (46)
Concentration
N/A
EC/CAS
105-87-3
Name of the chemical
2,6-Octadien-1-ol, 3,7-dimethyl-,1-acetate, (2E)- (40)
Concentration
N/A
General Information
Revision date
2018-09-19
Product name
KIMCARE MICROMIST Air Neutraliser / Morning Air Scent- ed
Emergency telephone
131126
Icons in SDS
Company Information
company name
Kimberly-Clark Australia Pty. Limited
e-mail address of the competent person responsible for the Safety Data Sheet
sdscontact@kcc.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H317, H319
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
H317
May cause an allergic skin reaction
H319
Causes serious eye irritation
Section 2
2.1 Classification of the substance or mixture
Flammable aerosols Category 1 Skin sensitisation Category 1 Serious eye damage/eye irri- Category 2A tation
Signal word
Danger
Hazard statements
H222 Extremely flammable aerosol. H317 May cause an allergic skin reaction. H319 Causes serious eye irritation.
Prevention
P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking. P211 Do not spray on an open flame or other ignition source. P251 Pressurized container: Do not pierce or burn, even after use.
Response
P302 + P352 IF ON SKIN: Wash with plenty of soap and water. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337 + P313 If eye irritation persists: Get medical advice/ at- tention.
Storage
P410 + P412 Protect from sunlight. Do not expose to tempera- tures exceeding 50 °C/ 122 °F.
Disposal
P501 Dispose of contents/ container to an approved waste disposal plant.
Other hazards which do not result in classification
None known.