Note: Ingredients listed on restricted chemical lists
EC/CAS
200-578-6/64-17-5
Name of the chemical
Ethanol
Concentration
30-<35%
EC/CAS
200-661-7/67-63-0
Name of the chemical
Propan-2-ol
Concentration
25-<30%
EC/CAS
200-746-9/71-23-8
Name of the chemical
Propan-1-ol
Concentration
10%
EC/CAS
203-928-6/112-02-7
Name of the chemical
C16-alkyltrimethylammonium chloride C18-alkyltrimethylammonium chloride
Concentration
<0,25%
General Information
Version
15
Revision date
2022-11-16
Product name
KiiltoClean Oy - Allsept S - 8061,8063,8064,8065,8175,8177,3101415 3101415
1.2.1 Relevant identified uses
antiseptic. For professional users only
1.2.2. Uses advised against
(Professional users) not defined
Emergency telephone
+358 9 471 977
Icons in SDS
Company Information
company name
KiiltoClean Oy
e-mail address of the competent person responsible for the Safety Data Sheet
asiakaspalvelu@kiilto.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H318, H336
Hazard statements
Code
Statements
H225
Highly flammable liquid and vapour
H318
Causes serious eye damage.
H336
May cause drowsiness or dizziness
Section 2
SECTION 2: Hazards identification
Regulation (EC) No. 1272/2008 Classification of the substance or mixture
Hazard statements
Eye Dam. 1: H318 - Causes serious eye damage. Flam. Liq. 2: H225 - Highly flammable liquid and vapour. STOT SE 3: H336 - May cause drowsiness or dizziness.
Precautionary statements
P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking P261: Avoid breathing dust/fume/gas/mist/vapours/spray. P305+P351+P338 IF IN EYES Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P312: Call a POISON CENTER/doctor if you feel unwell. P313: Get medical advice/attention. P403+P233: Store in a well-ventilated place. Keep container tightly closed.
2.3 Other hazards
Product fails to meet PBT/vPvB criteria Endocrine-disrupting properties: The product fails to meet the criteria. ** Changes with regards to the previous version
2.1 Classification of the substance or mixture
CLP Regulation (EC) No 1272/2008: Classification of this product has been carried out in accordance with CLP Regulation (EC) No 1272/2008. Eye Dam. 1: Serious eye damage, Category 1, H318 Flam. Liq. 2: Flammable liquids, Category 2, H225 STOT SE 3: Specific toxicity causing drowsiness and dizziness, single exposure, Category 3, H336