Note: Ingredients listed on restricted chemical lists
General Information
Revision date
2015-05-14
Product name
985 Soldering Flux
1.2.1 Relevant identified uses
Professional use of solder
Icons in SDS
Company Information
company name
Kester Inc
e-mail address of the competent person responsible for the Safety Data Sheet
EHS_Kester@kester.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H302, H302+H312+H332, H312, H332, H334, H335, H336
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
CLP CLASSIFICATION
GHS02 flame Flam. Liq. 2 H225 Highly flammable liquid and vapour. GHS08 health hazard Resp. Sens. 1 H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. GHS07 Acute Tox. 4 H302 Harmful if swallowed. Acute Tox. 4 H312 Harmful in contact with skin. Acute Tox. 4 H332 Harmful if inhaled. STOT SE 3 H335-H336 May cause respiratory irritation. May cause drowsiness or dizziness.
2.2 Label elements
Labelling according to Regulation (EC) No 1272/2008 The product is classified and labelled according to the CLP regulation.
Hazard pictograms
GHS02 GHS07 GHS08
Signal word
Danger
Hazard statements
H225 Highly flammable liquid and vapour. H302+H312+H332 Harmful if swallowed, in contact with skin or if inhaled. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. H335-H336 May cause respiratory irritation. May cause drowsiness or dizziness.
Precautionary statements
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P280 Wear protective gloves / eye protection. P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/ shower. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P403+P233 Store in a well-ventilated place. Keep container tightly closed. P501 Dispose of contents/container in accordance with local/regional/national/international regulations.
Additional information
For use in industrial installations only. Restricted to professional users.
PBT Substances
Not applicable
vPvB Substances
Not applicable *