Note: Ingredients listed on restricted chemical lists
EC/CAS
200-661-7/67-63-0
Name of the chemical
Propan-2-ol
Concentration
85-100%
EC/CAS
204-658-1/123-86-4
Name of the chemical
acetic acid, butyl ester
Concentration
3.0-5.0%
EC/CAS
204-673-3/124-04-9
Name of the chemical
adipic acid
Concentration
1.0-3.0%
General Information
Revision date
2015-01-09
Product name
961E Soldering Flux
1.2.1 Relevant identified uses
Professional use of solder
Emergency telephone
24-Hour Emergency Response Telephone Number (800) 424-9300
Icons in SDS
Company Information
company name
Kester Inc
e-mail address of the competent person responsible for the Safety Data Sheet
EHS_Kester@kester.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H319, H335, H336
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
CLP CLASSIFICATION
GHS02 flame Flam. Liq. 2 H225 Highly flammable liquid and vapour. GHS07 Eye Irrit. 2 H319 Causes serious eye irritation. STOT SE 3 H335-H336 May cause respiratory irritation. May cause drowsiness or dizziness.
2.2 Label elements
Labelling according to Regulation (EC) No 1272/2008 The product is classified and labelled according to the CLP regulation.
Hazard pictograms
GHS02 GHS07
Signal word
Danger
Hazardous Ingredients
Isopropanol n-butyl acetate
Hazard statements
H225 Highly flammable liquid and vapour. H319 Causes serious eye irritation. H335-H336 May cause respiratory irritation. May cause drowsiness or dizziness. (Continued from page 1)
Precautionary statements
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P280 Wear protective gloves / eye protection. P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/ shower. P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P370+P378 In case of fire Use for extinction CO2, powder or water spray P391 Collect spillage. Absorb liquid components with liquid-binding material. P403+P233 Store in a well-ventilated place. Keep container tightly closed. P501 Dispose of contents/container in accordance with local/regional/national/international regulations.
Additional information
Restricted to professional users.
PBT Substances
Not applicable
vPvB Substances
Not applicable *