Note: Ingredients listed on restricted chemical lists
EC/CAS
80-62-6
Name of the chemical
methacrylic acid, methyl ester
Concentration
≥10-<13%
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
1-5%
General Information
Revision date
2026-01-15
Product name
KEMPERTEC AC Repair Mortar
Emergency telephone
+1(656) 240-3099
Icons in SDS
Company Information
company name
KEMPER SYSTEM AMERICA, INC
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H315, H317, H351
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
GHS02 Flame Flammable liquids – Category 2 H225 Highly flammable liquid and vapour. GHS08 Health hazard Carcinogenicity – Category 2 H351 Suspected of causing cancer. GHS07 Skin Irritation - Category 2 H315 Causes skin irritation. Sensitization - skin – Category 1 H317 May cause an allergic skin reaction.
2.2 Label elements
The product is classified and labeled according to the Globally Harmonized System (GHS).
Signal word
Danger
Hazardous Ingredients
methyl methacrylate titanium dioxide (Contd. of page 1) Triethylene glycol dimethacrylate Fatty acids, C18, unsatd., dimers,reaction products with N,N-dimethyl-1,3-propanediamine and 1,3- propanediamine
Hazard statements
H225 Highly flammable liquid and vapour. H315 Causes skin irritation. H317 May cause an allergic skin reaction. H351 Suspected of causing cancer.
Precautionary statements
P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. P103 Read carefully and follow all instructions. P201 Obtain special instructions before use. P202 Do not handle until all safety precautions have been read and understood. P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P240 Ground and bond container and receiving equipment. P241 Use explosion-proof [electrical/ventilating/lighting] equipment. P243 Take action to prevent static discharges. P261 Avoid breathing mist/vapors/spray. P264 Wash contaminated body parts thoroughly after handling. P272 Contaminated work clothing should not be allowed out of the workplace. P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection. P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower]. P308+P313 IF exposed or concerned: Get medical advice/attention. P362+P364 Take off contaminated clothing and wash it before reuse. P333+P313 If skin irritation or rash occurs: Get medical advice/attention. P370+P378 In case of fire: Use CO2, powder or water spray to extinguish. P403+P235 Store in a well-ventilated place. Keep cool. P405 Store locked up. P501 Dispose of contents/container in accordance with local/regional/national/ international regulations. ꞏ Information pertaining to particular dangers for man and environment ꞏ NFPA ratings (scale 0 - 4) 3 Health = 1 1 0 Fire = 3 Reactivity = 0