Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-22-4
Name of the chemical
Silver
Concentration
N/A
EC/CAS
7440-50-8
Name of the chemical
Copper
Concentration
N/A
EC/CAS
231-131-3
Name of the chemical
Colloidal silver (nano) [INCI] (11)
Concentration
N/A
EC/CAS
231-159-6
Name of the chemical
Copper (nano) [INCI] (11), Colloidal Copper (nano) [INCI] (11)
Concentration
N/A
General Information
Revision date
2015-06-01
Product name
Argo-braze and Silver-flo Brazing filler metals
Product Synonyms
Argo-braze™ 60 & 60V * Argo-braze™ 61 & 61V * Argo-braze™ 63 & 63V * Argo-braze™ 7 *
Emergency telephone
+1-760-476-3961 (Access code: 333128
Icons in SDS
Company Information
company name
Johnson Matthey Metal Joining
e-mail address of the competent person responsible for the Safety Data Sheet
mj@matthey.com
GHS Information
Signal word
None
Section 2
EU Classification
Regulation (EC) No 1272/2008 as amended This mixture does not meet the criteria for classification according to Regulation (EC) 1272/2008 as amended. Hazard summary In its manufactured and shipped state, this product is considered to present low hazard. Elevated temperatures or mechanical action may form dust and fumes which may be irritating to the eyes, mucous membranes and respiratory tract. Heating above the melting point releases metallic oxides which may cause metal fume fever by inhalation. The symptoms are shivering, fever, malaise and muscular pain. Under normal conditions of use the level of metallic oxide fumes released are unlikely to exceed the specified workplace exposure limits (WELs). The nature of the primary use of these products may result in hazards which are not present at room temperature for massive metals: brazing requires melting of the products. The type of brazing operation / heating method used varies with each product. During furnace brazing type operations (reducing atmosphere, inert gas or vacuum) any fume evolved is usually contained within the furnace retort/chamber and therefore no direct fume hazard is presented by the products. However, evaporation of metallic vapor from the product into the retort/chamber during brazing operation could contaminate the inside of the retort/chamber and build up over time. Opening the retort/chamber or in circumstances where cleaning or maintenance of the retort/chamber or furnace ancillaries is undertaken, could present a metallic and metallic oxide dust hazard. This could well be a specific hazard associated with a vacuum furnace brazing chamber and its associated vacuum system ancillaries, particularly where brazing has been undertaken without the use of "Partial Pressure Brazing Technique". Where the products are being used to braze in air with a flux, bad brazing practice / overheating could result in the emissions of fumes in harmful concentrations above the specified workplace exposure limits (WELs).
2.2 Label elements
Label according to Regulation (EC) No. 1272/2008 as amended
Hazard pictograms
None.
Signal word
None.
Hazard statements
The mixture does not meet the criteria for classification.
Prevention
Observe good industrial hygiene practices.
Response
Wash thoroughly after handling.
Storage
Store away from incompatible materials.
Disposal
Dispose of waste and residues in accordance with local authority requirements.
Supplemental label elements
None
2.3 Other hazards
Not a PBT or vPvB substance or mixture.