Note: Ingredients listed on restricted chemical lists
EC/CAS
276-957-5/72869-86-4
Name of the chemical
11,14-Dioxa-2,9-diazaheptadec-16-enoic Acid, 4,4,6,16-tetramethyl-10,15-dioxo, 2-[(2-methyl-1-oxo-2-propenyl)oxy]ethyl ester (31)
Concentration
2.5-10%
EC/CAS
212-782-2/868-77-9
Name of the chemical
2-hydroxyethyl methacrylate
Concentration
2.5-10%
EC/CAS
202-327-6/94-36-0
Name of the chemical
Dibenzoyl peroxide
Concentration
<2.5%
General Information
Revision date
2019-12-12
Product name
Multilink Automix (Catalyst)
1.2.1 Relevant identified uses
Self-curing resin-based dental luting material with light-curing option
1.2.2. Uses advised against
No further relevant information available
Icons in SDS
Company Information
company name
Ivoclar Vivadent Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
sds@ivoclarvivadent.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H315, H317, H319, H335, H413
Hazard statements
Code
Statements
H315
Causes skin irritation
Section 2
2.1 Classification of the substance or mixture
Skin Irrit. 2 H315 Causes skin irritation. Eye Irrit. 2A H319 Causes serious eye irritation. Skin Sens. 1 H317 May cause an allergic skin reaction. STOT SE 3 H335 May cause respiratory irritation. Aquatic Chronic 4 H413 May cause long lasting harmful effects to aquatic life.
2.2 Label elements
The product is classified and labelled according to the Globally Harmonised System (GHS).
Hazard pictograms
GHS07
Hazardous Ingredients
urethane dimethacrylate 2-hydroxyethyl methacrylate dibenzoyl peroxide
Hazard statements
Causes skin irritation. Causes serious eye irritation. May cause an allergic skin reaction. (Contd. on page 2) NZ (Contd. of page 1) May cause respiratory irritation. May cause long lasting harmful effects to aquatic life.
Precautionary statements
Avoid contact during pregnancy/while nursing. Wear protective gloves/protective clothing/eye protection/face protection. If skin irritation or rash occurs: Get medical advice/attention. If eye irritation persists: Get medical advice/attention.
Additional information
Medical devices as defined in Directive 93/42/EEC and which are invasive or used in direct physical contact with the human body, are exempted from the provisions of Regulation (EC) No 1272/2008 (CLP/GHS) usually if they are in the finished state and intended for the final user.
PBT Substances
Not applicable
vPvB Substances
Not applicable