Note: Ingredients listed on restricted chemical lists
EC/CAS
212-782-2/868-77-9
Name of the chemical
2-hydroxyethyl methacrylate
Concentration
10-25%
EC/CAS
200-578-6/64-17-5
Name of the chemical
Ethanol
Concentration
10-25%
EC/CAS
220-688-8/2867-47-2
Name of the chemical
methacrylic acid, 2-(dimethylamino)-ethyl ester
Concentration
<2.5%
General Information
Revision date
2019-12-12
Product name
Adhese Universal
1.2.1 Relevant identified uses
Light-curing single-component dental adhesive
1.2.2. Uses advised against
No further relevant information available
Emergency telephone
0800 764 766 (National Poison Centre - 24 hours / 7 days
Icons in SDS
Company Information
company name
Ivoclar Vivadent Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
sds@ivoclarvivadent.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H226, H315, H317, H319, H333
Hazard statements
Code
Statements
H226
Flammable liquid and vapour
Section 2
2.1 Classification of the substance or mixture
Flam. Liq. 3 H226 Flammable liquid and vapour. Acute Tox. 5 H333 May be harmful if inhaled. Skin Irrit. 2 H315 Causes skin irritation. Eye Irrit. 2A H319 Causes serious eye irritation. Skin Sens. 1 H317 May cause an allergic skin reaction.
2.2 Label elements
The product is classified and labelled according to the Globally Harmonised System (GHS).
Hazard pictograms
GHS02 GHS07
Hazardous Ingredients
2-hydroxyethyl methacrylate 2-dimethylaminoethyl methacrylate Bis-GMA 1,10-decandiol dimethacrylate methacrylated phosphoric acid ester
Hazard statements
Flammable liquid and vapour. May be harmful if inhaled. (Contd. of page 1) Causes skin irritation. Causes serious eye irritation. May cause an allergic skin reaction.
Precautionary statements
Keep away from heat/sparks/open flames/hot surfaces. No smoking. Avoid breathing dust/fume/gas/mist/vapours/spray. Wear protective gloves/protective clothing/eye protection/face protection. If skin irritation or rash occurs: Get medical advice/attention. If eye irritation persists: Get medical advice/attention.
Additional information
Medical devices as defined in Directive 93/42/EEC and which are invasive or used in direct physical contact with the human body, are exempted from the provisions of Regulation (EC) No 1272/2008 (CLP/GHS) usually if they are in the finished state and intended for the final user.
PBT Substances
Not applicable
vPvB Substances
Not applicable