Note: Ingredients listed on restricted chemical lists
EC/CAS
80-62-6
Name of the chemical
methacrylic acid, methyl ester
Concentration
N/A
EC/CAS
97-90-5
Name of the chemical
methacrylic acid, diester with ethyleneglycol
Concentration
N/A
General Information
Revision date
2018-04-25
Product name
Telio Activator
1.2.1 Relevant identified uses
Auxiliary for dental technology
Icons in SDS
Company Information
company name
Ivoclar Vivadent Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H315, H317, H335
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
2.1 Classification of the substance or mixture
Flammable Liquids - Category 2 H225 Highly flammable liquid and vapour. Skin Irritation - Category 2 H315 Causes skin irritation. Skin Sensitizer - Category 1 H317 May cause an allergic skin reaction. Specific Target Organ Toxicity - Single Exposure - H335 May cause respiratory irritation. Category 3
2.2 Label elements
The product is classified and labeled according to the Globally Harmonized System (GHS).
Hazard pictograms
GHS02 GHS07
Signal word
Danger
Hazardous Ingredients
methyl methacrylate ethylene glycol dimethacrylate triethylene glycol dimethacrylate 2-(2-Hydroxy-5-methylphenyl)-benzotriazol; 2-(2H-Benzotriazol-2-yl)-p-kresol
Hazard statements
Highly flammable liquid and vapour. Causes skin irritation. May cause an allergic skin reaction. May cause respiratory irritation.
Precautionary statements
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Ground and bond container and receiving equipment. Use explosion-proof [electrical/ventilating/lighting] equipment. Use non-sparking tools. Take actions to prevent static discharges. Avoid breathing dust/fume/gas/mist/vapours/spray. Wash thoroughly after handling. Use only outdoors or in a well-ventilated area. Contaminated work clothing should not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower]. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell. Specific treatment (see on this label). If skin irritation or rash occurs: Get medical advice/attention. Take off contaminated clothing and wash it before reuse. In case of fire Use for extinction CO2, powder or water spray Store in a well-ventilated place. Keep container tightly closed. Store in a well-ventilated place. Keep cool. Store locked up. Dispose of contents/container in accordance with local/regional/national/international regulations.
Classification system
NFPA ratings (scale 0 - 4) Health = 2 3 Fire = 3 2 Reactivity = 2 ∙ HMIS-ratings (scale 0 - 4) HEALTH 2 Health = 2 FIRE 3 Fire = 3 REACTIVITY 2 Reactivity = 2