Note: Ingredients listed on restricted chemical lists
EC/CAS
75-28-5
Name of the chemical
iso-Butan, enthält 0,1% Butadien
Concentration
N/A
General Information
Revision date
2018-04-27
Product name
IPS e.max CAD Crystall./Glaze Spray
1.2.1 Relevant identified uses
Auxiliary for manufacture of dental prothesis
Emergency telephone
Emergency-Call USA - Infotrac: 1-800-535-5053
Icons in SDS
Company Information
company name
Ivoclar Vivadent Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H229, H319, H336
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
Section 2
2.1 Classification of the substance or mixture
Flammable Aerosols - Category 1 H222-H229 Extremely flammable aerosol. Pressurized container: may burst if heated. Eye Irritation - Category 2A H319 Causes serious eye irritation. Specific Target Organ Toxicity - Single Exposure - H336 May cause drowsiness or dizziness. Category 3
2.2 Label elements
The product is classified and labeled according to the Globally Harmonized System (GHS).
Hazard pictograms
GHS02 GHS07
Signal word
Danger
Hazardous Ingredients
propan-2-ol
Hazard statements
Extremely flammable aerosol. Causes serious eye irritation. May cause drowsiness or dizziness.
Precautionary statements
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Do not spray on an open flame or other ignition source. Do not pierce or burn, even after use. Avoid breathing dust/fume/gas/mist/vapours/spray. Wash thoroughly after handling. Use only outdoors or in a well-ventilated area. Wear protective gloves/protective clothing/eye protection/face protection. IF INHALED: Remove person to fresh air and keep comfortable for breathing. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Call a POISON CENTER/doctor if you feel unwell. If eye irritation persists: Get medical advice/attention. Store in a well-ventilated place. Keep container tightly closed. Store locked up. Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F. Dispose of contents/container in accordance with local/regional/national/international regulations.
Classification system
NFPA ratings (scale 0 - 4) Health = 1 0 Fire = 0 1 3 Reactivity = 3 ∙ HMIS-ratings (scale 0 - 4) HEALTH 1 Health = 1 FIRE 0 Fire = 0 REACTIVITY 3 Reactivity = 3