General Information
Revision date
2021-02-04
Product name
Devcon Sprayable Ceramic Thinner
Product name
Devcon Sprayable Ceramic Thinner
Identification on the label/Trade name
FLAMMABLE LIQUID, N.O.S. (contains methyl ethyl ketone)
Product Synonyms
S GHS AUS EN
CAS No.
78-93-3
Icons in SDS
Company Information
company name
ITW POLYMERS & FLUIDS
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H319, H335, H336
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
2.1 Classification of the substance or mixture
HAZARDOUS CHEMICAL. DANGEROUS GOODS. According to the WHS Regulations and the ADG Code. Poisons Schedule AS5
Classifications
1] Flammable Liquid Category 2, Eye Irritation Category 2A, Specific target organ toxicity - single exposure Category 3 (respiratory tract irritation), Specific target organ toxicity - single exposure Category 3 (narcotic effects) 1. Classified by Chemwatch; 2. Classification drawn from HCIS ; 3. Classification drawn from Regulation (EU) No 1272/2008 - Legend: Annex VI
Signal word
Danger
Hazard statements
H225 Highly flammable liquid and vapour. H319 Causes serious eye irritation. H335 May cause respiratory irritation. H336 May cause drowsiness or dizziness.
Prevention
P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking. P271 Use only outdoors or in a well-ventilated area. P240 Ground/bond container and receiving equipment. P241 Use explosion-proof electrical/ventilating/lighting/intrinsically safe equipment.
Response
P370+P378 In case of fire: Use alcohol resistant foam or normal protein foam for extinction. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P312 Call a POISON CENTER or doctor/physician if you feel unwell. P337+P313 If eye irritation persists: Get medical advice/attention.
Storage
P403+P235 Store in a well-ventilated place. Keep cool. P405 Store locked up.
Disposal
P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.