MICRON CSC BLACK

International Paint LLC

Revision date : 2013-07-23

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

General Information

Revision date

2013-07-23

Product name

MICRON CSC BLACK

1.2.1 Relevant identified uses

chemicals are listed in Section 2 if present at .1% or more. Additional regulatory information for specific chemical categories is included in

Icons in SDS

Company Information

company name

International Paint LLC

Section 2

Hazardous Ingredients

INFORMATION OSHA CAS No. Ingredient Name & % Source Exposure Data OSHA: No Established Limit ACGIH: No Established Limit NIOSH: 25 ppm TWA; 125 mg/m3 TWA Supplier: No Established Limit OHSA, CAN: No Established Limit 1,2,4−Trimethyl benzene 0000095−63−6 Mexico: No Established Limit 1.0 − 10% by Weight Brazil: No Established Limit Source Health Data NIOSH: No Established Limit Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No Group 1 No; Group 2A No; IARC: Group 2b No; Group 3 No; Group 4 No CAS No. Ingredient Name & % Source Exposure Data 100 ppm TWA; 435 mg/m3 TWA125 ppm STEL; 545 mg/m3 OSHA: STEL ACGIH: 100 ppm TWA125 ppm STEL 100 ppm TWA; 435 mg/m3 TWA125 ppm STEL; 545 mg/m3 NIOSH: STEL800 ppm IDLH (10% LEL) Supplier: No Established Limit OHSA, CAN: 100 ppm TWA125 ppm STEL Benzene, ethyl− 100 ppm TWA; 435 mg/m3 TWA125 ppm STEL; 545 mg/m3 0000100−41−4 Mexico: 1.0 − 10% by Weight STEL Brazil: 78 ppm TWA; 340 mg/m3 TWA Source Health Data NIOSH: Eye skin Source Carcinogen Data OSHA: Select Carcinogen: Yes NTP: Known Carcinogen No; Suspected Carcinogen No Group 1 No; Group 2A No; IARC: Group 2b Yes; Group 3 No; Group 4 No 1/8 CAS No. Ingredient Name & % Source Exposure Data 5 mg/m3 TWA (fume); 15 mg/m3 TWA (total dust); 5 mg/m3 OSHA: TWA (respirable fraction)10 mg/m3 STEL (fume) ACGIH: 2 mg/m3 TWA (respirable fraction)10 mg/m3 STEL (respirable fraction) 5 mg/m3 TWA (dust and fume)10 mg/m3 STEL (fume)15 NIOSH: mg/m3 Ceiling (dust)500 mg/m3 IDLH Supplier: No Established Limit OHSA, CAN: 2 mg/m3 TWA (respirable)10 mg/m3 STEL (respirable) Zinc oxide 5 mg/m3 TWA (fume); 10 mg/m3 TWA (dust)10 mg/m3 STEL 0001314−13−2 Mexico: 1.0 − 10% by Weight (fume) Brazil: No Established Limit Source Health Data NIOSH: Metal fume fever Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No Group 1 No; Group 2A No; IARC: Group 2b No; Group 3 No; Group 4 No CAS No. Ingredient Name & % Source Exposure Data OSHA: No Established Limit ACGIH: No Established Limit NIOSH: 0.1 mg/m3 TWA (fume, as Cu) Supplier: No Established Limit OHSA, CAN: No Established Limit Copper oxide 0001317−38−0 Mexico: No Established Limit 1.0 − 10% by Weight Brazil: No Established Limit Source Health Data NIOSH: No Established Limit Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No Group 1 No; Group 2A No; IARC: Group 2b No; Group 3 No; Group 4 No CAS No. Ingredient Name & % Source Exposure Data OSHA: No Established Limit ACGIH: No Established Limit NIOSH: No Established Limit Supplier: No Established Limit OHSA, CAN: No Established Limit Copper oxide (Cu2O) 0001317−39−1 Mexico: No Established Limit 25 − 50% by Weight Brazil: No Established Limit Source Health Data NIOSH: No Established Limit Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No IARC: Group 1 No; Group 2A No; Group 2b No; Group 3 No; Group 4 No CAS No. Ingredient Name & % Source Exposure Data 100 ppm TWA; 435 mg/m3 TWA150 ppm STEL; 655 mg/m3 OSHA: STEL ACGIH: 100 ppm TWA150 ppm STEL NIOSH: No Established Limit 2/8 Xylenes (o−, m−, p− isomers) 0001330−20−7 10 − 25% by Weight Supplier: No Established Limit OHSA, CAN: 100 ppm TWA150 ppm STEL 100 ppm TWA; 435 mg/m3 TWA150 ppm STEL; 655 mg/m3 Mexico: STEL Brazil: 78 ppm TWA; 340 mg/m3 TWA Source Health Data Central nervous system depressant; respiratory and eye NIOSH: irritation Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No Group 1 No; Group 2A No; IARC: Group 2b No; Group 3 Yes; Group 4 No CAS No. Ingredient Name & % Source Exposure Data OSHA: No Established Limit ACGIH: No Established Limit NIOSH: No Established Limit Supplier: No Established Limit OHSA, CAN: No Established Limit ETHYLTOLUENESULFONAMIDE 0008047−99−2 Mexico: No Established Limit 1.0 − 10% by Weight Brazil: No Established Limit Source Health Data NIOSH: No Established Limit Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No Group 1 No; Group 2A No; IARC: Group 2b No; Group 3 No; Group 4 No CAS No. Ingredient Name & % Source Exposure Data OSHA: No Established Limit ACGIH: No Established Limit NIOSH: No Established Limit Supplier: No Established Limit exposure by all routes should be carefully controlled to levels OHSA, CAN: as low as possible Rosin 0008050−09−7 Mexico: 0.1 mg/m3 TWA (as Formaldehyde) 1.0 − 10% by Weight Brazil: No Established Limit Source Health Data NIOSH: No Established Limit Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No Group 1 No; Group 2A No; IARC: Group 2b No; Group 3 No; Group 4 No CAS No. Ingredient Name & % Source Exposure Data OSHA: No Established Limit ACGIH: No Established Limit NIOSH: No Established Limit Supplier: No Established Limit OHSA, CAN: No Established Limit Petroleum naphtha 0064742−95−6 Mexico: No Established Limit 1.0 − 10% by Weight Brazil: No Established Limit Source Health Data NIOSH: No Established Limit 3/8 Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No IARC: Group 1 No; Group 2A No; Group 2b No; Group 3 No; Group 4 No CAS No. Ingredient Name & % Source Exposure Data OSHA: No Established Limit ACGIH: No Established Limit NIOSH: No Established Limit Supplier: No Established Limit OHSA, CAN: No Established Limit Glass, oxide, chemicals Mexico: No Established Limit 0065997−17−3 1.0 − 10% by Weight Brazil: No Established Limit Source Health Data NIOSH: No Established Limit Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No Group 1 No; Group 2A No; IARC: Group 2b No; Group 3 No; Group 4 No CAS No. Ingredient Name & % Source Exposure Data OSHA: No Established Limit ACGIH: No Established Limit NIOSH: No Established Limit Supplier: No Established Limit OHSA, CAN: No Established Limit TS−RV0611 Polymer Mexico: No Established Limit 1.0 − 10% by Weight Brazil: No Established Limit Source Health Data NIOSH: No Established Limit Source Carcinogen Data OSHA: Select Carcinogen: No NTP: Known Carcinogen No; Suspected Carcinogen No Group 1 No; Group 2A No; IARC: Group 2b No; Group 3 No; Group 4 No 3. HAZARD IDENTIFICATION NOTICE: Reports have associated repeated and prolonged occupational overexposure to solvents with permanent Overview: brain and nervous system damage. Intentional misuse by deliberately concentrating and inhaling the contents may be harmful or fatal. Avoid contact with eyes, skin and clothing. Inhalation: Harmful if inhaled. Causes nose and throat irritation. Vapors may affect the brain or nervous system causing dizziness, headache or nausea. Eyes: Causes severe eye irritation. Avoid contact with eyes. Skin: Causes skin irritation. May cause allergic skin reaction. May be harmful if absorbed through the skin. Harmful if swallowed. May cause abdominal pain, nausea, vomiting, diarrhea, or drowsiness. Can result in irritation of Ingestion: the mouth, stomach tissue and digestive tract. Possible cancer hazard. Contains an ingredient which may cause cancer based on animal data (See Section 2 and Chronic Effects: Section 15 for each ingredient). Risk of cancer depends on duration and level of exposure. HMIS Rating: Health: 2* Flammability: 3 Reactivity: 0

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.