Health risk rating 1
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

7440-67-7

Name of the chemical

Zirconium and its compounds, with the exception of the substances listed under reference number 50 in Annex III, and the zirconium lakes, pigments or salts of the colouring agents when listed in Annex IV

Concentration

N/A

EC/CAS

7778-74-7

Name of the chemical

Potassium Perchlorate

Concentration

N/A

Listed in

EC/CAS

9004-70-0

Name of the chemical

Nitrocellulose

Concentration

N/A

EC/CAS

122-39-4

Name of the chemical

Diphenylamine    

Concentration

N/A

EC/CAS

7782-42-5

Name of the chemical

Graphite

Concentration

N/A

EC/CAS

231-176-9

Name of the chemical

Zirconium and its compounds, with the exception of the substances listed under reference number 50 in Annex III, and the zirconium lakes, pigments or salts of the colouring agents when listed in Annex IV

Concentration

N/A

EC/CAS

204-539-4

Name of the chemical

Diphenylamine, when used as a fragrance ingredient

Concentration

N/A

EC/CAS

231-153-3

Name of the chemical

Carbon black

Concentration

N/A

General Information

Revision date

2018-11-28

Product name

IGP Buckle Pretensioner and IBP Buckle Pretensioner

1.2.1 Relevant identified uses

removing slack from the seat belt. Each pretensioner assembly includes a buckle, cable,

Icons in SDS

Company Information

company name

IMMI Ltd

Section 2

SECTION 2: Hazards identification

Emergency Overview: The tamper-resistant, sealed metal container poses no risk of chemical exposure before deployment. If the container vessel is incinerated, broken, drilled into, electric current is connected to the lead wires, or if installed improperly, a physical hazard may exist during deployment. The sealed device, a micro-gas generator (MGG), contains a mixture of proprietary pyrotechnic materials. DO NOT cut, drill, braze, solder, weld, strike, or probe the steel container. Do not drop, the buckle pretensioner may be damaged, exposing the MGGs and/or propellant. Do not attempt to service or repair. Intact systems pose no health hazard when handled in a way that prevents deployment of the system or damage to the system. Upon Activation, the seat belt buckle and cable will move rapidly, possibly causing mechanical damage or injury. Previously deployed systems present no health hazard. Upon activation, the combustion byproducts of the pyrotechnic materials are instantaneous and in negligible quantities. Avoid breathing or ingesting products of combustion. If exposed to combustion products, move to fresh air. Seek medical attention if necessary. Overexposure due to inhalation of combustion products could irritate respiratory system or aggravate existing respiratory condition. Avoid contact of combustion residue with skin; if necessary, flush with water. None expected when used as intended. Effluent gases from multiple deployments in testing situations may cause skin, eye, respiratory system, or mucus membrane irritation. Effluent gases

Potential health effects

in these situations must be effectively controlled through engineering systems designed and tested to remove applicable contaminants or PPE that will accomplish the same effect.

2.1 Classification of the substance or mixture

Class 9 – Miscellaneous Hazardous Materials

Hazard pictograms

Human Health Effects and Symptoms of Overexposure Inhalation Potential to irritate respiratory system or aggravate existing respiratory condition. Skin Contact Potential skin irritant. Eyes Potential eye irritant. Ingestion Not available. Carcinogenicity Not available.

Medical Conditions Generally Aggravated by Exposure

Exposure Respiratory conditions. Target Organs Not available.

Environmental effects

Not available.

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.