Note: Ingredients listed on restricted chemical lists
EC/CAS
7440-50-8
Name of the chemical
Copper
Concentration
5-30%
EC/CAS
1333-86-4
Name of the chemical
carbon black
Concentration
1-10%
EC/CAS
7440-02-0
Name of the chemical
Nickel
Concentration
0-5% 10-20% 4-10%
General Information
Product name
LITHIUM ION BATTERIES
Icons in SDS
Company Information
company name
If the original packaging is not on hand, please contact sonnen GmbH
e-mail address of the competent person responsible for the Safety Data Sheet
info@sonnen.de
Section 2
SECTION 2: Hazards identification
- Lithium ion cells are hermetically sealed units, and thus under normal usage associated with conditions, venting of electrolyte should not occur. vented - If the cells are subjected to abnormal heating or other abuse conditions, electrolyte electrolyte and electrolyte decomposition products can vaporize and be vented from cells. - Accumulation of liquid electrolyte is unlikely in the case of abnormal heating. Vented gases are a common early indicator of a thermal runaway reaction – an abnormal and hazardous condition. - If gases or smoke are observed to be escaping from the product, evacuate the area and notify a first responder team and/or the local fire department. - Gases or smoke exiting a lithium ion battery pack are likely to be flammable and could ignite unexpectedly as the condition that led to cell venting may also cause ignition of the vent gases. - A venting product should only be approached with extreme caution by trained first responders equipped with appropriate personal protective equipment (PPE). - Cell vent gas composition will depend upon a number of factors, including cell composition, cell state of charge, and the cause of cell venting. - Vent gases may include volatile organic compounds (VOCs) (such as alkyl- carbonates, methane, ethylene, and ethane), hydrogen gas, carbon dioxide, carbon monoxide, soot, and particulates containing oxides of nickel, aluminum, lithium, copper. Additionally PF5 , POF3 and HF vapours may form. - Warning. Avoid contact with vented gas. - Vented gases may irritate the eyes, skin, and throat. - Cell vent gases are typically hot: upon exit from a cell, vent gas temperatures can exceed 600 °C (1,110 °F). Contact with hot gases can cause thermal burns. - Vented electrolyte is flammable and may ignite on contact with a competent ignition source such as an open flame, spark or a sufficiently heated surface. - Vented electrolyte may also ignite on contact with cells undergoing a thermal runaway reaction.