Note: Ingredients listed on restricted chemical lists
General Information
Revision date
2013-08-30
Product name
SOLVE-IT NO. 192
Product Synonyms
O-91020R
Emergency telephone
(800) 424-9300
Icons in SDS
Company Information
company name
Hydrite Chemical Co
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
Signal word
Danger GHS Classification Substance or mixture corrosive to metals Category 1 Skin Corrosion/Irritation Category 1B Serious Eye Damage/Eye Irritation Category 1 Specific Target Organ Systemic Toxicity (STOT) - Repeated Exposure Category 2
Hazard statements
May be corrosive to metals. Causes severe skin burns and eye damage. May cause damage to organs (teeth, respiratory system) through prolonged or repeated exposure (by inhalation).
Prevention
Keep only in original container. Do not breathe dust, fume, gas, mist, vapours or spray. Wash thoroughly after handling. Wear gloves, eye and face protection and protective clothing.
Response
IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water. IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physician. Specific treatment (see on this label). Wash contaminated clothing before reuse. Absorb spillage to prevent material damage.
Storage
Store in a secure manner. Store in corrosive resistant container with a resistant inner liner.
Disposal
Dispose of in accordance with local, regional and international regulations. Not Otherwise Classified: May react violently with water. Percentage of Components with Unknown Acute Toxicity Oral: Dermal 35.3 %
2.1 Classification of the substance or mixture
Substance or mixture corrosive to metals Category 1 Skin Corrosion/Irritation Category 1B Serious Eye Damage/Eye Irritation Category 1 Specific Target Organ Systemic Toxicity (STOT) - Repeated Exposure Category 2 Hazard Statements: May be corrosive to metals. Causes severe skin burns and eye damage. May cause damage to organs (teeth, respiratory system) through prolonged or repeated exposure (by inhalation).