Note: Ingredients listed on restricted chemical lists
EC/CAS
123-86-4
Name of the chemical
acetic acid, butyl ester
Concentration
N/A
EC/CAS
108-10-1
Name of the chemical
4-methylpentan-2-one; isobutyl methyl ketone (MIBK)
Concentration
N/A
EC/CAS
67-56-1
Name of the chemical
Methanol
Concentration
N/A
EC/CAS
64742-89-8
Name of the chemical
Solvent naphtha (petroleum), light aliph
Concentration
N/A
General Information
Revision date
2016-07-28
Product name
No. 330 Release
Product Synonyms
Complex hydrocarbon based solution
1.2.1 Relevant identified uses
Lacquer blanket coating for easy release of thin paper stocks
1.2.2. Uses advised against
Not intended for any other use other than the recommended use of this product Persons handling and/or using this product should be trained regarding handling and use
Manufacturer Name
HURST CHEMICAL COMPANY
Emergency telephone
(800) 424-9300
Icons in SDS
Company Information
company name
HURST CHEMICAL COMPANY
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
HMIS
Health hazards
3 0 = Least 3 = High Flammability = 3 1 = Slight 4= Extreme CLASS Reactivity = 0 2 = Moderate Other: Safety glasses, organic vapor respirator and gloves. Flash Point °F: 21° TCC Autoignition temperature, °F: N/A Flammable class: IB
Signal word
Danger
Hazard statements
Unusual fire and explosion hazards: This material is combustible and may be ignited by heat or flame, sparks or static electricity. If container is not properly cooled it may explode in heat of fire. Some ingredients may cause cancer or are suspected of causing cancer. Harmful in contact with skin.
Precautionary statements
Wash affected areas thoroughly after handling. Do not eat, drink or smoke when using this product. Wear protective gloves/protective clothing/eye protection/face protection. Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Keep away from heat/sparks/open flames/hot surfaces. Keep container tightly closed. Use explosion-proof electrical/ventilating/lighting/and other equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Mixture composition and information on ingredients are described in Section 3.