General Information
Revision date
2022-01-13
Product name
OXYGEN, COMPRESSED
Product Synonyms
CALIBRATING GAS MIX, OXYGEN, AVIATOR"S BR, OXYGEN,TECHNICAL
CAS No.
7782-44-7
Emergency telephone
+1 (800) 424 9300
Icons in SDS
Company Information
company name
Hudson Technologies Company
e-mail address of the competent person responsible for the Safety Data Sheet
information@hudsontech.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H270, H280
Hazard statements
Code
Statements
H270
May cause or intensify fire; oxidiser
Section 2
2.1 Classification of the substance or mixture
US CFR 1910.1200 Ox. Gas 1; May cause or intensify fire; oxidizer. Gases under pressure; Press. Gas; Compressed gas.
2.2 Label elements
Product Name OXYGEN, COMPRESSED.
Hazard pictograms
GHS03 GHS04
Signal word
Danger.
Hazard statements
H270: May cause or intensify fire; oxidizer. H280: Contains gas under pressure; may explode if heated.
Precautionary statements
P202: Do not handle until all safety precautions have been read and understood. P220: Keep/Store away from clothing/combustible materials. P244: Keep valves and fittings free from oil and grease. P271+P403: Use and store only outdoors or in a well-ventilated place. P370+P376 In case of fire, use Water, Dry powder P410+P403: Protect from sunlight. Store in a well-ventilated place.
2.3 Other hazards
Breathing 80% or more oxygen at atmospheric pressure for more than a few hours may cause nasal stuffiness, cough, sore throat, chest pain and breathing difficulty. Breathing oxygen at higher pressure increases the likelihood of adverse effects within a shorter time period. Breathing pure oxygen under pressure may cause lung damage and also central nervous system effects resulting in dizziness, poor coordination, tingling sensation, visual and hearing disturbances, muscular twitching, unconsciousness and convulsions. Breathing oxygen under pressure may cause prolongation of adaptation to darkness and reduced peripheral vision.
Additional information
CGA-PG05: Use a back flow preventive device in the piping. CGA-PG20 + CGA-PG10: Use only with equipment of compatible materials of construction and rated for cylinder pressure. CGA-PG22: Use only with equipment cleaned for oxygen service. CGA-PG21: Open valve slowly. CGA-PG06: Close valve after each use and when empty. CGA-PG02: Protect from sunlight when ambient temperature exceeds 52 °C (125 °F). CGA-PG27: Read and follow the Safety Data Sheet (SDS) before use. This SDS is available in languages other than English.