Note: Ingredients listed on restricted chemical lists
EC/CAS
231-159-6/7440-50-8
Name of the chemical
Copper
Concentration
N/A
EC/CAS
231-791-2/7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
N/A
General Information
Version
New
Revision date
2022-01-11
Product name
ARCEL Resins - Standard Grades
1.2.1 Relevant identified uses
For Laboratory Use
Emergency telephone
800-535-5053
Icons in SDS
Company Information
company name
High-Purity Standards
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
Classification Skin Corrosion/Irritation, Category 1B Serious Eye Damage/ Eye Irritation, Category 1
Signal word
Danger
Hazard statements
Causes severe skin burns and eye damage. Causes serious eye damage
Precautionary statements
Wear protective gloves/clothing and eye/face protection. Wash thoroughly after handling.
2.1 Classification of the substance or mixture
Skin Corrosion/Irritation, Category 1B Serious Eye Damage/ Eye Irritation, Category 1 Labeling: Symbol: Signal Word: Danger. Hazard Statement: Causes severe skin burns and eye damage. Causes serious eye damage. Precautionary Statement: Wear protective gloves/clothing and eye/face protection. Wash thoroughly after handling. Section 3. Composition Component CAS/EINECS Registry # Percent Concentration Copper 7440-50-8/231-159-6 1 Nitric Acid 7697-37-2/ 231-714-2 4 Water, deionized 7732-18-5/ 231-791-2 Balance Section 4. First Aid Measures IF ON SKIN (or hair) : Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before reuse. Call a physician if irritation develops. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. Call a physician. May cause nausea, vomiting, and diarrhea. IF INHALED: Remove to fresh air and keep at rest in a position comfortable for breathing. Target Organs: Eyes, skin. Section 5. Fire Fighting Measures 1 Safety Data Sheet No. 10M14-1 Date: October 3, 2011 10.00 mg/mL Copper in 4% HNO3 Fire & Explosion hazards: While nitric acid is not combustible, it is a strong oxidizing agent that can react with combustible materials; however, it is present in limited quantities in this solution. NOx compounds can be released in case of fire. Extinguishing Media: Use any extinguishing media that is suitable for the surrounding area. Use a water spray to dilute nitric acid and to absorb liberated nitrogen oxides. Specific Methods: Firefighters should wear proper protective equipment and self-contained breathing apparatus with full face piece operated in positive pressure mode. Section 6. Accidental Release Measures