Note: Ingredients listed on restricted chemical lists
EC/CAS
67-56-1
Name of the chemical
Methanol
Concentration
0-0.5
EC/CAS
50-00-0
Name of the chemical
Formaldehyde
Concentration
0-0.5
EC/CAS
7732-18-5
Name of the chemical
Water, distilled, conductivity or of similar purity H2O
Concentration
10-30
General Information
Version
7.1
Revision date
2024-06-28
Product name
Cascomel M5651
Product Synonyms
Not Available
Chemical name
Not Applicable
1.2.1 Relevant identified uses
Particle Board resin Use according to manufacturer"s directions
Emergency telephone
+61 8 9725 5800, +61 1800 951 288, +61 3 9573 3188
Icons in SDS
Company Information
company name
Hexion Australia Pty Ltd
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H315, H319, H350, H360D
Hazard statements
Code
Statements
H315
Causes skin irritation
Section 2
SECTION 2: Hazards identification
No 1272/2008 Classification of the substance or mixture
Signal word
Danger
Hazard statements
H315 Causes skin irritation. H319 Causes serious eye irritation. H350 May cause cancer. H360D May damage the unborn child.
Prevention
Page 1 continued P201 Obtain special instructions before use. P280 Wear protective gloves, protective clothing, eye protection and face protection. P264 Wash all exposed external body areas thoroughly after handling.
Response
P308+P313 IF exposed or concerned: Get medical advice/ attention. P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P337+P313 If eye irritation persists: Get medical advice/attention. P302+P352 IF ON SKIN: Wash with plenty of water. P332+P313 If skin irritation occurs: Get medical advice/attention. P362+P364 Take off contaminated clothing and wash it before reuse.
Storage
P405 Store locked up.
Disposal
P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.
2.1 Classification of the substance or mixture
Category 1B Legend: 1. Classified by Chemwatch; 2. Classification drawn from HCIS; 3. Classification drawn from Regulation (EU) No 1272/2008 - Annex VI