Note: Ingredients listed on restricted chemical lists
EC/CAS
67-63-0
Name of the chemical
Propan-2-ol
Concentration
60-100%
EC/CAS
99-97-8
Name of the chemical
N,N-dimethyl-p-toluidine
Concentration
1-10%
EC/CAS
128-37-0
Name of the chemical
2,6-di-tert-butyl-p-cresol
Concentration
0,1-1%
General Information
Revision date
2014-10-20
Product name
LOCTITE SF 712 ACTIVATOR known as Tak Pak 712 Accelerator
1.2.1 Relevant identified uses
Accelerator
supplier name
Sheet
Emergency telephone
+86 532 8388 9090
Icons in SDS
Company Information
company name
Henkel Malaysia Sdn Bhd
e-mail address of the competent person responsible for the Safety Data Sheet
ap-ua-psra.sea@henkel.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H319, H336
Hazard statements
Code
Statements
H225
Highly flammable liquid and vapour
H319
Causes serious eye irritation
H336
May cause drowsiness or dizziness
Section 2
SECTION 2: Hazards identification
GHS Classification Hazard Class Flammable liquids Serious eye irritation Specific target organ toxicity - Hazard Category Target organ Category 2 Category 3 Central Nervous System single exposure
Signal word
Danger
Hazard statements
H225 Highly flammable liquid and vapor. H319 Causes serious eye irritation. H336 May cause drowsiness or dizziness.
Prevention
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P261 Avoid breathing vapors, mist, or spray.
Response
P337+P313 If eye irritation persists: Get medical advice/attention.
2.1 Classification of the substance or mixture
Hazard Class Hazard Category Target organ Flammable liquids Category 2 Serious eye irritation Category 2 Specific target organ toxicity - Category 3 Central Nervous System single exposure