Note: Ingredients listed on restricted chemical lists
EC/CAS
200-661-7/67-63-0
Name of the chemical
Propan-2-ol
Concentration
>=50-<=100%
EC/CAS
232-475-7/110-94-1
Name of the chemical
glutaric acid
Concentration
>=1-<3%
EC/CAS
204-673-3/8050-09-7
Name of the chemical
Rosin
Concentration
>=1-<10%
EC/CAS
204-673-3/124-04-9
Name of the chemical
adipic acid
Concentration
>=1-<3%
General Information
Revision date
2015-06-01
Product name
LOCTITE MF R301 5L known as MFR301 LIQUID FLUX
Product Synonyms
Propan-2-ol
1.2.1 Relevant identified uses
Liquid Flux
Icons in SDS
Company Information
company name
Henkel Ireland
e-mail address of the competent person responsible for the Safety Data Sheet
ua-productsafety.uk@uk.henkel.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H304, H317, H319, H336
Hazard statements
Code
Statements
H225
Highly flammable liquid and vapour
H304
May be fatal if swallowed and enters airways
H317
May cause an allergic skin reaction
H319
Causes serious eye irritation
H336
May cause drowsiness or dizziness
Section 2
CLP CLASSIFICATION
Flammable liquids Category 2 H225 Highly flammable liquid and vapor. Serious eye irritation Category 2 H319 Causes serious eye irritation. Skin sensitizer Category 1 H317 May cause an allergic skin reaction. Specific target organ toxicity - single exposure Category 3 H336 May cause drowsiness or dizziness. Target organ: Central Nervous System
Aspiration hazard
Category 1 H304 May be fatal if swallowed and enters airways.
2.2 Label elements
CLP)
Signal word
Danger
Hazard statements
H225 Highly flammable liquid and vapor. H304 May be fatal if swallowed and enters airways. H317 May cause an allergic skin reaction. H319 Causes serious eye irritation. H336 May cause drowsiness or dizziness.
Precautionary statements
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. P331 Do NOT induce vomiting.
Prevention
No smoking. P280 Wear protective gloves. P261 Avoid breathing vapours.
Response
P301+P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor. P333+P313 If skin irritation or rash occurs: Get medical advice/attention. P337+P313 If eye irritation persists: Get medical advice/attention.
2.3 Other hazards
Fumes evolved at soldering temperatures will irritate the nose, throat and lungs. Prolonged or repeated exposure to flux fumes may result in sensitisation in sensitive workers.