GHS07 GHS02
Health risk rating 3
Safety risk rating 3
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

67-64-1

Name of the chemical

acetone

Concentration

75.0%

EC/CAS

64-17-5

Name of the chemical

Ethanol

Concentration

22.5%

EC/CAS

67-63-0

Name of the chemical

Propan-2-ol

Concentration

1.3%

General Information

Revision date

2024-10-28

Product name

Decolorizer, Fast (75% Acetone, 25% Alcohol)

Product Synonyms

None

1.2.1 Relevant identified uses

Used to stain microorganisms from cultures or specimens by the differential Gram method

Emergency telephone

(800) 424-9300

Icons in SDS

GHS02 GHS07

Company Information

company name

Hardy Diagnostics

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H225, H302, H313, H319, H332, H336

Hazard statements

Code

Statements

H225

Highly Flammable liquid and vapour

Section 2

SECTION 2: Hazards identification

GHS Classification in Accordance with 29 CFR 1910 (OSHA HCS): Classification of substance or mixture

Signal word

Danger

Hazard statements

H225 Highly flammable liquid and vapor H319 Causes serious eye irritation H302 Harmful if swallowed H332 Harmful if inhaled H313 May be harmful in contact with skin H336 May cause drowsiness or dizziness

Precautionary statements

P210 Keep away from heat, hot surfaces, sparks, open flames, and other ignition sources. No smoking. P233 Keep container tightly closed. P240 Ground and bond container and receiving equipment. P241 Use explosion-proof equipment. P242 Use non-sparking tools. P243 Take action to prevent static discharges. P260 Do not breathe fumes, mists, or vapors. P264 Wash hands thoroughly after handling. P270 Do not eat, drink, or smoke when using this product. P271 Use only outdoors or in a well-ventilated area P280 Wear protective clothes and eye protection. P302+P352 IF ON SKIN: Wash with plenty of water P303+P361+P353 IF ON SKIN: Take off immediately all contaminated clothing. Rinse skin with water or shower. P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P308+P311 If exposed or concerned, call a POISON CENTER. P312 Call a POISON CENTER/doctor if you feel unwell P321 Specific treatment (see supplemental first aid instructions on this label). P330 Rinse mouth P337+P313 If eye irritation persists: Get medical attention. P362+P364 Take off contaminated clothing and wash it before reuse P370+P378 In case of fire, use water spray, carbon dioxide, dry chemical powder, or appropriate foam to extinguish. P403+P235 Store in a well-ventilated place. Keep cool. P405 Store locked up. P501 Dispose of contents or container at an approved waste disposal facility, according to applicable regulations. 2.3. Hazards not otherwise classified or not covered by GHS No data available.

2.1 Classification of the substance or mixture

GHS Classification in Accordance with 29 CFR 1910 (OSHA HCS) Flammable Liquid (Category 2), H225 Eye Irritant (Category 2A), H319 Acute Toxicity – Oral (Category 4), H302 Acute Toxicity – Inhalation (Category 4), H332 Acute Toxicity – Dermal (Category 5), H313 Specific Target Organ Toxicity, Single Exposure (Category 3), H336

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.