Note: Ingredients listed on restricted chemical lists
EC/CAS
7631-86-9
Name of the chemical
Silver adsorbed on silicon dioxide
Concentration
2.5-10
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
2.5-10
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
1-2.5
EC/CAS
14464-46-1
Name of the chemical
Cristobalit (s. u. TRGS 906)
Concentration
0.1-1
EC/CAS
108-95-2
Name of the chemical
Phenol
Concentration
0.1-1
EC/CAS
50-00-0
Name of the chemical
Formaldehyde
Concentration
0-0.1 20-40
General Information
Revision date
2017-10-11
Product name
ANKORBOND C
1.2.2. Uses advised against
Users should be informed of the potential presence of respirable dust and respirable crystalline silica as well as their potential hazards. Appropriate training in the proper use and handling of this material should be provided as required under applicable regulations
Manufacturer Name
HarbisonWalker International
Emergency telephone
CHEMTREC 24 HOUR
Icons in SDS
Company Information
company name
HarbisonWalker International
GHS Information
Signal word
Danger
Section 2
Physical hazards
Not classified.
Health hazards
Carcinogenicity Category 1A Specific target organ toxicity, repeated Category 1 exposure
Environmental hazards
Not classified. OSHA defined hazards Not classified.
Signal word
Danger
Hazard statements
May cause cancer. Causes damage to organs through prolonged or repeated exposure.
Prevention
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Do not breathe dust. Wash thoroughly after handling. Do not eat, drink or smoke when using this product. Wear protective gloves/protective clothing/eye protection/face protection.
Response
If exposed or concerned: Get medical advice/attention.
Storage
Store locked up.
Disposal
Dispose of contents/container in accordance with local/regional/national/international regulations. Hazard(s) not otherwise None known.
Additional information
Users should be informed of the potential presence of respirable dust and respirable crystalline silica as well as their potential hazards. Overexposure to the respirable dust of crystalline silica (quartz or cristobalite, less than or equal to 5 microns in size) may lead to silicosis in humans, which is a progressive and irreversible lung disease. Appropriate training in the proper use and handling of this material should be provided as required under applicable regulations.