Note: Ingredients listed on restricted chemical lists
EC/CAS
65996-61-4
Name of the chemical
Cellulose pulp
Concentration
N/A
EC/CAS
7440-44-0
Name of the chemical
Carbon black
Concentration
N/A
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
N/A
General Information
Revision date
2015-05-11
Product name
Gusmer Cellulose Carbon Filter Sheet with Bentonite
Product Synonyms
Cellulose Filter Sheet
1.2.2. Uses advised against
To avoid exposure to airborne dust, do not damage or abrade filter material
Emergency telephone
911
Icons in SDS
Company Information
company name
Gusmer Enterprises, Inc
GHS Information
Signal word
Danger
Section 2
2.1 Classification of the substance or mixture
Not considered a hazardous material when used in its normal state and use. This product does not release respirable dust when used in its normal state and uses; however this product does contains crystalline silica (CS), which is considered a hazard by inhalation.
OSHA HCS Classification
Carcinogenicity (Category 1A) Specific target organ toxicity - repeated exposure, inhalation (Category 1)
Signal word
Danger
Precautionary statements
May cause cancer by inhalation. Obtain special instructions before use. Causes damage to lungs through prolonged or repeated exposure if inhaled. Do not handle until all safety precautions have been read and understood. Do not breathe dust. Use personal protective equipment as required. IF exposed or concerned: Get medical advice/attention. Store locked up. Dispose of contents/ container to an approved waste disposal plant. Ventilation recommended. 2.3 Emergency Overview
Appearance/Odor
Black, carbon-impregnated filter sheets, generally odorless.
2.3 Other hazards
Warning This product does not release respirable dust when used in its normal state and uses; however this product does contain crystalline silica (CS), which is considered a hazard by inhalation. IARC has classified inhalation of CS as carcinogenic for humans. CS is listed by NTP as a known human carcinogen. Inhalation of CS is also a known cause of silicosis, a noncancerous lung disease. Activated carbon (especially when wet) can deplete oxygen from air in enclosed spaces, and dangerously low levels of oxygen may result. Prior to entering a confined space that contains or previously contained activated carbon, the space should be evaluated for oxygen and carbon monoxide concentrations, and any other hazards, by a qualified person. Product may form combustible dust concentrations in air during processing. Specifically, in instances where product dust is suspended in air in sufficient concentrations and in proximity to an ignition source. Product as supplied and shipped does not constitute a dust hazard. Users of this product should examine the potential to generate dusts during handling and processing and related combustibility hazards and controls.