GHS05 GHS07 GHS08 GHS09
Health risk rating 5
Safety risk rating 1
Environmental risk rating 5

Note: Ingredients listed on restricted chemical lists

EC/CAS

7440-31-5

Name of the chemical

Organometallic tin

Concentration

<1

EC/CAS

1317-36-8

Name of the chemical

Lead monoxide (lead oxide)

Concentration

<0.1

EC/CAS

1309-60-0

Name of the chemical

Lead peroxide

Concentration

15 to 25

EC/CAS

7440-39-3

Name of the chemical

Barium

Concentration

<2

EC/CAS

7664-93-9

Name of the chemical

sulphuric acid

Concentration

10 to 20

EC/CAS

79-94-7

Name of the chemical

Tetrabromobisphenol A(TBBPA)

Concentration

<1.2%

EC/CAS

1309-64-4

Name of the chemical

Diantimontrioxid

Concentration

<0.3%

General Information

Version

23

Revision date

2025-10-15

Product name

Valve Regulated Lead-Acid (VRLA) Industrial Battery

Icons in SDS

GHS05 GHS07 GHS08 GHS09 M004 M009 M010 M011 M013 T031 T050

Company Information

company name

GS Yuasa Battery Europe Ltd

GHS Information

Signal word

DANGER

Hazard Codes

Hazard statements (CLP)

H302, H314, H315, H318, H360D, H360Fd, H362, H372, H400, H410

Hazard statements

Code

Statements

H302

Harmful if swallowed

H314

Causes severe skin burns and eye damage.

H315

Causes skin irritation

H318

Causes serious eye damage.

H360D

May damage the unborn child.

H360Fd

May damage fertility. Suspected of damaging the unborn child.

H362

May cause harm to breast-fed children

H372

Causes damage to organs through prolonged or repeated exposure

H400

Very toxic to aquatic life

H410

Very toxic to aquatic life with long lasting effects

Section 2

SECTION 2: Hazards identification

According to Regulation (EC) No. 1272/2008 (CLP)] Battery, wet, non-spillable, electric storage (Mixture) Substance classification: UN 2800 Product Codes: EN & ENL, NP, NPC, NPH, NPL, NPW, RE, REC, REW, SW, SWL, SWL+, TEV, FXH, UXH, UXL, Yucel, YuVolt, YPC and YFT Series of Industrial VRLA Batteries 1.2 Relevant Identified Uses Of The Relevant identified uses: Product And Uses Advised Standby: Telecoms; UPS; alarm and security systems; emergency lighting; utility switching Against Cyclic: Golf Trolleys, portable tools, portable lighting, wheelchairs, remote telemetry Energy storage: Photovoltaic energy systems (PVES); wind turbines Uses advised against: Automotive, commercial, and agricultural SLI applications Reason why uses advised against: High starting and ignition current demands beyond the design of internal and external current carrying components 1.3 Details Of The Supplier Of The Supplier: GS Yuasa Battery Europe Ltd, Safety Date Sheet Address: Unit 8, Ignition Park, Swindon, Wiltshire SN3 5FB United Kingdom Contact: Mike TAYLOR (General Manager – Technical & Compliance) Tel: (+44) 07733 302 242 e-mail: mike.taylor@yuasaeurope.com Language: English language only Available: Office hours only 8am to 4pm (08 00 to 16 00) National Contacts: France: GS Yuasa Battery France S.A. Contact: Anthony JAMBON (Technical & Training Manager) Tel: (+33) 0474-95-90-95 e-mail: anthony.jambon@gs-yuasa.fr Language: French & English Germany: GS Yuasa Battery Germany GmbH Contact: Thomas WALLRAFF (Manager Reserve & Renewable Energy &Technical) Tel: (+49) 02151-82095-27 e-mail: Thomas.Wallraff@gs-yuasa.de Language: German & English Iberia: GS Yuasa Battery Iberia S.A. Contact: Fernando GARCIA (Industrial Division Sales Manager) Tel: (+34) 091 748 98 19 e-mail: fernando.garcia@gs-yuasa.es Language: Spanish & English Italy: GS Yuasa Battery Italy Srl. Contact: Roberto FICCADENTI (Technical Assistance) Tel: (+39) 02-3800-91-08 e-mail: roberto.ficcadenti@gs-yuasa.it Language: Italian & English UK: GS Yuasa Battery Sales UK Ltd. Contact: Matthew ELWICK (Technical Manager) Tel: (+44) 01793-833-560 e-mail matthew.elwick@gs-yuasa.uk Language: English language only Sweden: GS Yuasa Battery Nordic Contact: Michael KRAFTH (Country Manager) Tel: (+46) 36 47110 e-mail michael.krafth@gs-yuasa.se Language: English & Swedish 1.4 Emergency telephone number: GS Yuasa Battery Manufacturing UK Ltd. Contact: Mike TAYLOR (General Manager – Technical & Compliance) Tel: (+44) 07733 302 242 Opening Hours: Only available during office hours, 8am to 4pm (08 00 to 16 00) Language: English language only Available: Office hours only 8am to 4pm (08 00 to 16 00) AUSTRALIA CONTACT: NEW ZEALAND CONTACT: Getinge Australia Pty Ltd Getinge Australia (NZ Branch) Suite 701, Level 7, 11 Help Street 600 Great South Rd, Ground Floor, Building A, Unit D Chatswood NSW 2067 Australia Ellerslie Auckland 1051 NZ Phone: 1800 438 464 Phone: 0800 1 438 464 Emergency: 1800 074 234 Emergency: 0800 46 881 In the event of the internal battery components being exposed Classification of the substance or mixture H302 Acute toxicity 4 H314 Skin Corr.1A H315 Skin damage/irritation 1 According to Regulation H318 Eye damage/irritation 1

Adverse physicochemical, human health and environmental effects

No additional information available

Hazard pictograms

GHS05 GHS07 GHS08 GHS09

Signal word

DANGER H302 Harmful if swallowed H314 Causes severe skin burns and eye damage H315 Causes skin irritation H318 Causes serious eye damage

Hazard statements

H360D May damage the unborn child (CLP) H360Fd May damage fertility. Suspected of damaging the unborn child H362 May cause harm to breast-fed children H372 Causes damage to organs through prolonged or repeated exposure H400 Very toxic to aquatic life H410 Very toxic to aquatic life with long lasting effects P201 Obtain special instructions before use

Precautionary statements

P202 Do not handle until all safety precautions have been read and understood P260 Do not breathe dust/fume/gas/mists/vapours/spray P264 Wash …. Thoroughly after handling P270 Do not eat, drink or smoke when using this product P273 Avoid release to the environment P280 Wear protective gloves/protective clothing/eye protection IF ON SKIN (or hair): Take off Immediately all contaminated P303, 361, 353 clothing. Rinse SKIN with water [or shower]. P301, 330, 331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting P304, 340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. IF IN EYES: Rinse cautiously with water for several minutes. P305, 351, 338 Remove contact lenses if present and easy to do - continue rinsing.

2.3 Other hazards

VRLA Battery Mechanical VRLA Batteries can be heavy. Correct manual handling techniques and/or mechanical lifting aides (e.g. Fork Lift Truck) must be used. Electrical VRLA Batteries can contain large amounts of electrical energy which can give very high discharge currents and severe electrical shock if the terminals are short circuited. Chemical • The VRLA Battery presents no chemical hazards during the normal operation provided the recommendations for handling, storage, transport and usage are observed. • VRLA Batteries emit hydrogen gas which is highly flammable and will form explosive mixtures in air from approx. 4% to 76%. This can be ignited by a spark at any voltage, naked flames or other sources of ignition. • If the battery is broken and the internal components exposed, hazards may exist which require careful attention.

2.1 Classification of the substance or mixture

H302 Acute toxicity 4 H314 Skin Corr.1A H315 Skin damage/irritation 1 According to Regulation H318 Eye damage/irritation 1 (EC) No. 1272/2008 (CLP) H360D Reproductive toxicity 1A,1B Full text of H phrases – H360Fd Repr.1A see section 16 H362 May harm breast fed children H372 STOT RE1 H400 Aquatic Acute 1 H410 Aquatic Chronic 1 Adverse physicochemical, human health and environmental effects No additional information available

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.