Note: Ingredients listed on restricted chemical lists
EC/CAS
304-340-3/64742-48-9
Name of the chemical
Naphtha (petroleum), hydrotreated heavy
Concentration
2.5-10
EC/CAS
64742-95-6
Name of the chemical
Solvent naphtha (petroleum), light arom
Concentration
2.5-10
EC/CAS
7631-86-9
Name of the chemical
Silver adsorbed on silicon dioxide
Concentration
1.0-2.5
EC/CAS
8052-41-3
Name of the chemical
Stoddard Solvent; Naphtha (petroleum), hydrodesulfurized heavy
Concentration
0.1-1.0
EC/CAS
91-20-3
Name of the chemical
Naphthalene,3
Concentration
0.1-1.0
EC/CAS
96-29-7
Name of the chemical
2-Butanonoxim (2020/1182)
Concentration
0.1-1.0
EC/CAS
136-52-7
Name of the chemical
Cobalt bis(2-ethylhexanoate)
Concentration
0.1-1.0
General Information
Revision date
2016-06-17
Product name
XO Rust Oil Base Enamel Coating Metallic Aluminum
Product name
XO Rust Oil Base Enamel Coating Metallic Aluminum
Identification on the label/Trade name
XO-10
1.2.1 Relevant identified uses
Metallic Aluminum Enamel Coating
1.2.2. Uses advised against
No Information
supplier name
GPM
Icons in SDS
Company Information
company name
GPM
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
GHS Classification EMERGENCY OVERVIEW: FLAMMABLE liquid and vapor.
2.1 Classification of the substance or mixture
Carc. 1B, Flam. Liq. 3, Muta. 1B Symbol(s) of Product Signal Word Danger GHS HAZARD STATEMENTS Carcinogenicity, category 1B H350 Suspected of causing cancer. Flammable Liquid, category 3 H226 Flammable liquid and vapor. Germ Cell Mutagenicity, category 1B H340 Suspected of causing genetic defects .
Signal word
Danger
Hazard statements
Carcinogenicity, category 1B Flammable Liquid, category 3 Germ Cell Mutagenicity, category 1B H350 Suspected of causing cancer. H226 Flammable liquid and vapor. H340 Suspected of causing genetic defects .
Precautionary statements
P201 Obtain special instructions before use. P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P281 Use personal protective equipment as required. P308+P313 IF exposed or concerned: Get medical advice/attention. P240 Ground/bond container and receiving equipment. P241 Use explosion-proof electrical/ventilating/lighting/…/ equipment. P242 Use only non-sparking tools. P243 Take precautionary measures against static discharge.