Note: Ingredients listed on restricted chemical lists
EC/CAS
1328-53-6
Name of the chemical
(29H,31H-Phthalocyaninato(2-)- N29,N30,N31,N32)copper (Pigment Blue 15; CI 74160) when used as a substance in hair dye products
Concentration
N/A
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
N/A
EC/CAS
64742-48-9
Name of the chemical
Naphtha (petroleum), hydrotreated heavy
Concentration
N/A
EC/CAS
96-29-7
Name of the chemical
2-Butanonoxim (2020/1182)
Concentration
N/A
EC/CAS
111-76-2
Name of the chemical
Ethylene glycol monobutyl ether (EGBE)
Concentration
N/A
EC/CAS
1333-86-4
Name of the chemical
carbon black
Concentration
N/A
General Information
Revision date
2016-06-17
Product name
XO-11
1.2.1 Relevant identified uses
Rust Preventative Coating
1.2.2. Uses advised against
No Information
supplier name
GPM
Icons in SDS
Company Information
company name
GPM
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H224, H340, H350
Hazard statements
Code
Statements
H224
Extremely flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
GHS Classification EMERGENCY OVERVIEW: FLAMMABLE liquid and vapor.
2.1 Classification of the substance or mixture
Carc. 1B, Flam. Liq. 1, Muta. 1B Symbol(s) of Product
Signal word
Danger
Hazard statements
Carcinogenicity, category 1B H350 Suspected of causing cancer. Flammable Liquid, category 1 H224 Extremely flammable liquid and vapour. Germ Cell Mutagenicity, category 1B H340 Suspected of causing genetic defects .
Precautionary statements
P201 Obtain special instructions before use. P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 Keep container tightly closed. P281 Use personal protective equipment as required. P308+P313 IF exposed or concerned: Get medical advice/attention. P403+P235 Store in a well-ventilated place. Keep cool. P240 Ground/bond container and receiving equipment. P241 Use explosion-proof electrical/ventilating/lighting/…/ equipment. P242 Use only non-sparking tools. P243 Take precautionary measures against static discharge.