General Information
Revision date
2009-03-13
Product name
LPS 1 (AEROSOL SPRAY CAN)
1.2.1 Relevant identified uses
A spray lubricant designed to displace moisture from mechanical and electrical equipment, provide light-duty lubrication and short-term rust prevention
supplier name
Geocel Limited
Emergency telephone
+44 (0)1752 202060, +44 (0)1752 334384, +001 703-527-3887
Icons in SDS
Company Information
company name
Geocel Limited
Section 2
SECTION 2: Hazards identification
Weight Percent Distillates (Petroleum), 265-149-8 64742-47-8 [Xn] R65 70-80% Hydrotreated Light Distillates (Petroleum), 265-148-2 64742-46-7 Note N 20-30% Hydrotreated Middle* Carbon Dioxide 204-696-9 124-38-9 NC 1-5 % *This component has been tested by Supplier. According to Supplier, the component complies with the criteria of Note N in Annex I of 67/548/EEC, and is exempt from a classification of T; R45. (Contains less than 3% PNA per IP346) See “Section 11: Toxicological Information” for information regarding the classification of substances. Section 3 – Hazards Identification Human and This preparation is not classified according to the latest adaptations of European Union Directives Environmental 67/548/EEC and 1999/45/EC. Hazards This product will combust when subjected to ignition sources. Do not spray on a naked flame or any incandescent material. Remark: The classification for aspiration hazards (R65), does not apply for products placed on the market in aerosol containers. (EU-Directive 67/548 Annex VI 9.4). Inhalation of concentrated petroleum distillate mist or vapours can cause central nervous system (CNS) depression.