Note: Ingredients listed on restricted chemical lists
EC/CAS
13463-67-7
Name of the chemical
Reaction mass of titanium dioxide and silver chloride
Concentration
N/A
EC/CAS
123-86-4
Name of the chemical
acetic acid, butyl ester
Concentration
N/A
EC/CAS
9004-36-8
Name of the chemical
cellulose acetate butyrate
Concentration
N/A
EC/CAS
21645-51-2
Name of the chemical
Aluminium hydroxide
Concentration
N/A
EC/CAS
7631-86-9
Name of the chemical
Silver adsorbed on silicon dioxide
Concentration
N/A
General Information
Product name
GEM VAR CONV. VARNISH, FLAT, WHITE
1.2.1 Relevant identified uses
A protective and/or decorative finish or accompanying paint product. Not recommended for any other of the chemical and use not detailed on product data sheet or label
Manufacturer Name
GEMINI INDUSTRIES, INC
Icons in SDS
Company Information
company name
Gemini Industries, Inc
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H315, H318, H335, H336, H340, H350, H360, H373, H412
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
Flammable liquid and vapours. Keep away from heat, sparks and open flame. Avoid contact with skin, eyes and clothing. Do not breathe vapours, mists or aerosols. Do not ingest. If ingested consult physician immediately and Summary show this Safety Data Sheet. Wear eye protection, gloves and other protective clothing that are adapted to the task being performed and the risks involved. WHMIS 2015/OSHA HCS 2012/GHS Flammable liquids (Category 2) Skin corrosion/irritation (Category 2) Serious eye damage/eye irritation (Category 1) Germ cell mutagenicity (Category 1) Carcinogenicity (Category 1) Reproductive toxicity (Category 1) Specific target organ toxicity, single exposure (Category 3) Specific target organ toxicity, repeated exposure (Category 2)
Other hazards which do not result in classification
Long-term hazard to the aquatic environment (Category 3). DANGER H225: Highly flammable liquid and vapour H318: Causes serious eye damage H350: May cause cancer H340: May cause genetic defects H360: May damage fertility or the unborn child H315: Causes skin irritation H335: May cause respiratory irritation H336: May cause drowsiness or dizziness H373: May cause damage to organs through prolonged or repeated exposure by inhalation H412: Harmful to aquatic life with long lasting effects P201: Obtain special instructions before use. P202: Do not handle until all safety precautions have been read and understood. P210: Keep away from heat, sparks, open flames and other ignition sources. No smoking. P240: Ground or bond container and receiving equipment. P241: Use explosion-proof electrical, ventilating, lighting and all material-handling equipment. P242: Use only non-sparking tools. P243: Take precautionary measures against static discharge. P260: Do not breathe mist, vapours and spray. P264: Wash skin thoroughly after handling. P271: Use only outdoors or in a well-ventilated area. P273: Avoid release to the environment. P280: Wear protective gloves, protective clothing and eye protection. P303+361+353 IF ON SKIN (or hair) Remove immediately all contaminated clothing. Rinse skin with water and soap or take a shower if necessary. P332+313 If skin irritation occurs Get medical advice or attention P304+340 IF INHALED Remove victim to fresh air and keep at rest in a position comfortable for breathing P312: Call a POISON CENTER or doctor/physician if you feel unwell. P305+351+338 IF IN EYES Rinse continuously with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing. P310: Immediately call a doctor/physician. P308+313 IF exposed or concerned Get medical advice/attention P321: Specific treatment (see section 4 of SDS or on this label). P362+364: Take off contaminated clothing and wash before reuse. P370+378 In case of fire Use the National Fire Protection Association Class B extinguisher for extinction P403+P235+P233: Store in a well-ventilated place. Keep container tightly closed. Keep cool. P405: Store locked up. P501: Dispose of contents and container to a licensed chemical disposal agency in accordance with local, regional and national regulations.