Note: Ingredients listed on restricted chemical lists
EC/CAS
108-88-3
Name of the chemical
Toluene
Concentration
N/A
EC/CAS
123-86-4
Name of the chemical
acetic acid, butyl ester
Concentration
N/A
EC/CAS
1333-86-4
Name of the chemical
carbon black
Concentration
N/A
EC/CAS
96-29-7
Name of the chemical
2-Butanonoxim (2020/1182)
Concentration
N/A
General Information
Revision date
2015-05-29
Product name
SPRYBL BLACK
1.2.1 Relevant identified uses
A protective and/or decorative finish or accompanying product (reference label or product data sheet for more information)
Manufacturer Name
Spill
Icons in SDS
Company Information
company name
Gemini Coatings
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H222, H225, H280, H351
Hazard statements
Code
Statements
H222
Extremely flammable aerosol
Section 2
Classifications
Flammable aerosol 1 Flammable aerosol class 1 Gas under pressure Compressed gas Entirely gaseous at -50°C Carcinogen 2 Limited evidence of human or animal carcinogenicity
Precautionary statements
H222 Extremely flammable material P201 Obtain special instructions before use H225 Highly flammable liquid and vapour P202 Do not handle until all safety H280 Contains gas under pressure; precautions have been read and may explode if heated understood H351 Suspected of causing cancer P210 Keep away from heat/sparks/open flames/hot surfaces – No smoking P211 Do not spray on an open flame or other igntion source P233 Keep container tightly closed P240 Ground/bond container and receiving equipment P241 Use explosion-proof electrical/ventilating/light/mixers/equipm ent P242 Use only non-sparking tools P243 Take precautionary measures against static discharge P251 Pressurized container – Do not pierce or burn, even after use P280 Wear protective gloves/protective clothing/eye protection/face protection P281 Use personal protective equipment as required P303+P361+P35 IF ON SKIN (or hair): Remove/Take off 3 immediately all contaminated clothing. Rinse skin with water/shower P308+P313 IF exposed or concerned: Get medical advice/attention P370+P378 In case of fire: Use the NFPA Class B extinguisher for extinction P405 Store locked up P403+P235 Store in a well ventilated place. Keep cool P410+P403 Protect from sunlight. Store in a well ventilated place P410+P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F P501 Do not flush to sewer, watershed or waterway. Dispose of product in accordance with applicable local, county, state and federal regulations.
Signal word
Danger