Note: Ingredients listed on restricted chemical lists
EC/CAS
124-38-9
Name of the chemical
Carbon dioxide CO2
Concentration
97.8-98.2
General Information
Revision date
2016-05-18
Product name
ECO2FUME Fumigant Gas
Chemical name
Mixture of phosphine and carbon dioxide
1.2.1 Relevant identified uses
Fumigant CYTEC INDUSTRIES INC., FIVE GARRET MOUNTAIN PLAZA, WOODLAND PARK, NEW JERSEY 07424, USA
Emergency telephone
+61-3-9663-2130, +86 0532 83889090, +65 3158 1074, +65 3158 1198, +1-905-356-8310, +44 (0) 1235 239 670, +44 (0) 1235 239 671, +56-2-2-247-3600, +52-376-73 74122, +1-703-527-3887, 1-800-424-9300
Icons in SDS
Company Information
company name
CYTEC INDUSTRIES INC.
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
2.1 Classification of the substance or mixture
Gases Under Pressure - Liquefied Gas Acute Toxicity (Inhalation) Hazard Category 3 Skin Corrosion / Irritation Hazard Category 2 Serious Eye Damage / Eye Irritation Hazard Category 2A Simple Asphyxiant
Signal word
Danger
Hazard statements
Contains gas under pressure; may explode if heated Toxic if inhaled Causes skin irritation Causes serious eye irritation May displace oxygen and cause rapid suffocation
Precautionary statements
Avoid breathing dust/fume/gas/mist/vapours/spray. Use only outdoors or in a well-ventilated area. Wash face, hands and any exposed skin thoroughly after handling. Wear protective gloves/protective clothing/eye protection/face protection. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER or doctor/physician. Specific treatment (see supplemental first aid instructions on this label). IF ON SKIN: Wash with plenty of soap and water. Take off all contaminated clothing and wash it before reuse. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Protect from sunlight. Store in a well-ventilated place. Store in a well-ventilated place. Keep container tightly closed. Store locked up. Dispose of contents/container in accordance with local and national regulations.
2.3 Other hazards
HNOC), Other Hazards Contact with liquified gas may cause frostbite Asphyxiant gas - depletes available oxygen in breathing air Phosphine gas may react with certain metals and cause corrosion, especially at higher temperatures and relative humidity. −⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯−−