Note: Ingredients listed on restricted chemical lists
EC/CAS
138-86-3
Name of the chemical
1-methyl-4-prop-1-en-2-yl-cyclohexene; dl-limonene (racemic); Dipentene (37)
Concentration
N/A
EC/CAS
27138-31-4
Name of the chemical
DPGDB, Oxydipropyl dibenzoate
Concentration
N/A
EC/CAS
205-341-0
Name of the chemical
1-methyl-4-prop-1-en-2-yl-cyclohexene; dl-limonene (racemic); Dipentene (37)
Concentration
N/A
General Information
Revision date
2011-09-29
Product name
Flowfresh/Flowcrete Multipack Base A
1.2.1 Relevant identified uses
Polyol based component for multi-pack Flowfresh and Flowcrete polyurethane resin floor screeds Mixed product is applied using a trowel. This component does not contain any antimicrobial agent See the relevant technical data sheets for mixing and application instructions
1.2.2. Uses advised against
Home DIY and spray applications
Manufacturer Name
Flowcrete UK Ltd.
Icons in SDS
Company Information
company name
Flowcrete UK Ltd.
e-mail address of the competent person responsible for the Safety Data Sheet
ehs.uk@flowcrete.com
Section 2
EU Classification
Directive DPD 1994/45/EC - Xi; Irritant. Skin sensitizer. R43.
Environmental hazards
R52/53
2.2 Label elements
Labelling to Regulation (EC) no 1907/2006
Hazardous Ingredients
dipentene. dipropylene glycol dibenzoate.
Hazard pictograms
Irritant
R-phrase(s)
R43 : May cause sensitization by skin contact. R52/53 Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
S-phrase(s)
S28 After contact with skin, wash immediately with plenty of water and soap. S36/37/39 : Wear suitable protective clothing, gloves and eye/face protection. S61 Special provisions statement None.
2.3 Other hazards
PBT or vPvB: Does not meet the criteria (Regulation No 1207/2006, Annex XIII). UK Workplace exposure limits - none set for this material or its constituent chemicals. Repeated and /or prolonged exposure may cause an allergic eczema reaction/sensitization. Once sensitized, an individual may produce an allergic reaction every time they are in contact with dipentene. Persons who are sensitized to dipentene should not work with this material.