General Information
Version
4
Revision date
2024-03-30
Product name
Calcium perchlorate hydrate
Product Synonyms
No information available
CAS No.
13477-36-6
Emergency telephone
1-800-234-7437, 001-800-227-6701, +32 14 57 52 11, 001-201-796-7100, +32 14 57 52 99, 001-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Fisher Scientific
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
Signal word
Danger
Hazard statements
May intensify fire; oxidizer Causes skin irritation Causes serious eye irritation May cause respiratory irritation
Prevention
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking Keep/Store away from clothing/combustible materials Take any precaution to avoid mixing with combustibles Avoid breathing dust/fume/gas/mist/vapors/spray Wash face, hands and any exposed skin thoroughly after handling Use only outdoors or in a well-ventilated area Wear protective gloves/protective clothing/eye protection/face protection
Response
IF ON SKIN: Wash with plenty of soap and water IF INHALED: Remove person to fresh air and keep comfortable for breathing IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing Call a POISON CENTER/ doctor if you feel unwell In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish Take off contaminated clothing and wash it before reuse
Storage
Store in a well-ventilated place. Keep container tightly closed Store locked up
Disposal
Dispose of contents/container to an approved waste disposal plant