General Information
Version
4
Revision date
2021-12-25
Product name
Azetidine
Product Synonyms
Trimethylene imine
CAS No.
503-29-7
Manufacturer Name
Fisher Scientific
Emergency telephone
1-800-234-7437, +32 14 57 52 11, 001-201-796-7100, +32 14 57 52 99, 001-800-424-9300, 001-703-527-3887
Icons in SDS
Company Information
company name
Fisher Scientific
GHS Information
Signal word
Danger
Section 2
SECTION 2: Hazards identification
Signal word
Danger
Hazard statements
Highly flammable liquid and vapor Causes severe skin burns and eye damage
Prevention
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking Keep container tightly closed Ground/bond container and receiving equipment Use explosion-proof electrical/ventilating/lighting/equipment Use only non-sparking tools Take precautionary measures against static discharges Do not breathe dust/fumes/gas/mist/vapours/spray Wash face, hands and any exposed skin thoroughly after handling Wear protective gloves/protective clothing/eye protection/face protection
Response
IF SWALLOWED: Rinse mouth. Do NOT induce vomiting IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower IF INHALED: Remove person to fresh air and keep comfortable for breathing IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing Immediately call a POISON CENTER/doctor Wash contaminated clothing before reuse In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish
Storage
Store locked up Store in a well-ventilated place. Keep cool
Disposal
Dispose of contents/container to an approved waste disposal plant