Note: Ingredients listed on restricted chemical lists
EC/CAS
110-54-3
Name of the chemical
Hexane
Concentration
N/A
General Information
Revision date
2014-03-03
Product name
Vapor Shield Solvent Based Primer
Product name
Vapor Shield Solvent Based Primer
Identification on the label/Trade name
% (by wt)
Product Synonyms
Dimethyl Ketone
Chemical name
Mixture
CAS No.
110-54-3
Manufacturer Name
Firestone Building Products Company, LLC
Icons in SDS
Company Information
company name
Firestone Building Products Company, LLC
Section 2
SECTION 2: Hazards identification
Principle Routes of Exposure
Signs and Symptoms of Inhalation, skin absorption Eye contact may cause moderate eye irritation, redness, Exposure tearing and blurred vision. Prolonged or repeated skin contact may cause irritation, dermatitis and drying of the skin. Absorption through intact skin may contribute to an individual's overall exposure. Inhalation may cause respiratory system irritation and central nervous system depression (narcosis) characterized by headache, dizziness, muscular weakness and fatigue. May cause unconsciousness if exposure is excessive. Acetone LD50 (oral, rat) >5000 mg/kg Acetone LC50 (inhalation, rat) 50 mg/l/4 hr Hexane LD50 (skin) >2000 mg/kg Hexane LC50 (inhalation, rat) >20 mg/l/4 hr Heptane LD50 (skin) >2000 mg/kg Heptane LC50 (inhalation, rat) >50 mg/l/4 hr
Medical Conditions Generally Aggravated by Exposure
Exposure to this product may aggravate pre-existing skin and by Exposure respiratory diseases. Individuals with neurological diseases should avoid exposure to Hexane.
Potential chronic health
May affect the nervous system. Carcinogenicity None SECTION 4 FIRST AID MEASURES First Aid Procedures If this material contacts the eyes, hold eyelids open and flush immediately with a gentle stream of water for at least 15 minutes, preferably at an eyewash fountain. Get medical attention. In case of skin contact, wash affected area with soap and water. In case of inhalation, remove to fresh uncontaminated air. Administer oxygen if breathing is labored. Give artificial respiration if breathing has stopped. Get medical attention immediately if oxygen or artificial respiration is administered. In case of accidental ingestion, do not induce vomiting. Get medical attention and advise the physician of the nature of the material. SECTION 5 FIRE FIGHTING PROCEDURES Suitable Extinguishing Media Foam, carbon dioxide, dry chemical, and vaporizing liquid type extinguishing agents may all be suitable for extinguishing fires involving this product. Water may be ineffective, but should be used to keep fire-exposed containers cool. If a leak or spill has ignited, use water to disperse the vapors and to protect men attempting to stop a leak. Water spray may be used to flush spills away from exposures. Hazardous Combustion Products: Possible decomposition products that may occur during a fire include oxides of carbon and nitrogen, aldehydes, ketone, acrolein, halogenated compounds, methanol, formaldehyde, acetic acid, hydrogen peroxide, methane, and ethylene oxide. Recommended Fire Fighting Wear impermeable protective clothing and self-contained breathing Procedures: apparatus. Toxic fumes and vapors may be evolved. Minimize the breathing of gases, vapors, fumes or decomposition products. Use supplied-air breathing equipment for enclosed or confined spaces or as otherwise needed. Unusual Fire and Explosion This product is volatile and gives off invisible vapors. Either the Hazards: liquid or vapor may settle in low areas or travel some distance along the ground or surface to ignition sources where they may ignite or explode. SECTION 6: PRECAUTIONS FOR SAFE HANDLING AND USE