Note: Ingredients listed on restricted chemical lists
EC/CAS
8052-41-3
Name of the chemical
Stoddard solvent; Low boiling point naphtha — unspecified (A colourless, refined petroleum distillate that is free from rancid or objectionable odours and that boils in a range of approximately 149 °C to 205 °C.)
Concentration
N/A
EC/CAS
64742-80-9
Name of the chemical
Distillates (petroleum), hydrodesulfurized middle
Concentration
N/A
EC/CAS
51274-00-1
Name of the chemical
Iron Oxide Yellow
Concentration
N/A
General Information
Revision date
2009-04-28
Product name
844-0982 CHROMA-CHEM LEAD FREE ORANGE UO
1.2.1 Relevant identified uses
Non-aqueous colorant Preparation
Manufacturer Name
Evonik
Emergency telephone
Product Regulatory Services
Icons in SDS
Company Information
company name
Evonik Degussa Corporation
Section 2
SECTION 2: Hazards identification
EMERGENCY OVERVIEW *** Form-paste Color-orange Odor-Sweet ether-like odor. May cause eye, skin and respiratory tract irritation. Combustible liquid and vapor.
Potential health effects
Eye contact Irritating. May cause tearing, reddening and/or swelling. Skin Contact A moderate skin irritant based on testing of similar CHROMA-CHEM® base mixtures. Prolonged or repeated contact may cause irritation. Prolonged skin contact with large amounts of ether acetates may cause drowsiness. May cause skin sensitization, an allergic reaction, which becomes evident on re-exposure to this nervous system effects including dizziness, weakness, fatigue, nausea, headache, possible unconsciousness and even death. Ingestion May cause gastrointestinal irritation, nausea, vomiting, and diarrhea.
Health hazards
High vapor concentrations (3000 ppm) of propylene glycol monomethyl ether acetate caused upper respiratory irritation and liver and kidney effects in subchronic animal testing. The relevance of these results to humans is not known. Health studies have shown that many petroleum hydrocarbons pose potential human health risks which may vary from person to person. As a precaution, exposure to liquids, vapors, mists or fumes should be minimized. Prolonged inhalation of iron oxide dust is known to produce a condition known as siderosis. On X- rays it appears to be a benign pneumoconiosis and is not associated with pulmonary fibrosis or disability unless there is concurrent exposure to other fibrosis producing materials such as silica. Because this product is a free-flowing liquid or paste, dust inhalation is not an expected route of exposure.