Note: Ingredients listed on restricted chemical lists
EC/CAS
471-480-0/29118-24-9
Name of the chemical
(E)-1,3,3,3-Tetrafluoro-1-propene
Concentration
>=5-<10
EC/CAS
220-120-9/2634-33-5
Name of the chemical
1,2-Benzisothiazol-3(2H)-one
Concentration
>=0,0025-< >=0,05%
EC/CAS
220-239-6/2682-20-4
Name of the chemical
2-Methyl-2H-isothiazol-3-one
Concentration
>=0,0002-< >=0,0015%
General Information
Version
1.0
Revision date
2020-12-16
Product name
Everbuild P18 Plumbers Gas Leak Detector
1.2.1 Relevant identified uses
Spray application
Emergency telephone
0044 113 240 3456
Icons in SDS
Company Information
company name
Everbuild - A Sika Company
e-mail address of the competent person responsible for the Safety Data Sheet
everbuild.sds@uk.sika.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H229, H319, H412
Hazard statements
Code
Statements
H229
Pressurized container: may burst if heated
Section 2
SECTION 2: Hazards identification
Regulation (EC) No. 1272/2008 Classification of the substance or mixture
Signal word
Warning
Hazard statements
H229 Pressurised container: May burst if heated. H319 Causes serious eye irritation. H412 Harmful to aquatic life with long lasting ef- fects. P101 If medical advice is needed, have product
Precautionary statements
container or label at hand. P102 Keep out of reach of children.
Prevention
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P251 Do not pierce or burn, even after use.
Storage
P410 + P412 Protect from sunlight. Do not expose to tem- peratures exceeding 50 °C/ 122 °F.
Disposal
P501 Dispose of contents/container in accordance with local regulation.
Additional information
EUH208
Contains
1,2-benzisothiazol-3(2H)-one (BIT), 2-methyl-2H-isothiazol-3-one (MIT). May produce an allergic reaction.
2.3 Other hazards
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
2.1 Classification of the substance or mixture
Classification (REGULATION (EC) No 1272/2008) Aerosols, Category 3 H229: Pressurised container: May burst if heated. Eye irritation, Category 2 H319: Causes serious eye irritation. Long-term (chronic) aquatic hazard, Cat- H412: Harmful to aquatic life with long lasting ef- egory 3 fects.