Note: Ingredients listed on restricted chemical lists
EC/CAS
231-131-3/7440-22-4
Name of the chemical
Silver
Concentration
N/A
EC/CAS
235-186-4/12125-02-9
Name of the chemical
Ammonium chloride
Concentration
N/A
EC/CAS
200-578-6/64-17-5
Name of the chemical
Ethanol
Concentration
N/A
EC/CAS
231-667-8/7681-49-4
Name of the chemical
Sodium fluoride
Concentration
N/A
EC/CAS
203-473-3/107-21-1
Name of the chemical
Ethane-1,2-diol
Concentration
N/A
General Information
Product name
STAINTIN 157 PA
Product Synonyms
Eutectic 157PA
1.2.1 Relevant identified uses
Soldering Paste (Lead < 0.1 %)
supplier name
N94 W14355 GARWIN MACE DRIVE
Manufacturer Name
EUTECTIC CORPORATION
Emergency telephone
1-800-424-9300, +1 703-527-3887
Icons in SDS
Company Information
company name
EUTECTIC CORPORATION
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H301, H302, H314, H315, H319, H400, H410
Hazard statements
Code
Statements
H301
Toxic if swallowed
Section 2
SECTION 2: Hazards identification
EMERGENCY OVERVIEW: DANGER: Causes burns to skin, eyes, and respiratory system. Product is chemically stable and inert and does not pose a fire hazard as shipped. Non-Flammable: However, heat and flames used during brazing and soldering can ignite combustibles. Refer to American National Standard Z49.1 for fire prevention during welding and soldering.
Potential health effects
Swallowing: May cause burns of mouth and throat. Inhalation: Irritation to respiratory system. Coughing and sneezing. Existing lung disorders will be aggravated. Severe exposure may cause pulmonary edema. Metal fume fever may result from inhaling zinc oxide, which is a possible decomposition product at high temperatures. Brazing/welding vapours and fumes from brazing/welding may cause metal fumes fever. Symptoms can appear 4 to 12 hours after. (headache, dizziness, dryness, cough, nausea and fever) May cause irritation by prolonged inhalation of brazing/welding fumes. Skin Contact: Dermatitis, possible chemical burns, and corrosive to skin. Existing disorders will be aggravated. Eye Contact: Irritation to the eyes, tearing, burn of the eye surfaces, corrosive to the eyes, may cause blindness. ROUTES OF ENTRY: Primary route of entry is the respiratory system. Other possible routes are eyes, ingestion, and/or skin contact.
Acute Health Hazards
and CHRONIC HEALTH HAZARDS see Section 11 WARNING: This product contains or produces a chemical known to the State of California to cause birth defects (or other reproductive harm) and cancer. (California Health & Safety Code 25249.5 et seq.). WARNING: avoid breathing welding fumes and gases; they may dangerous to your health. Always use adequate ventilation and use appropriate personal protection equipment. CARCINOGENICITY WELDING FUMES (not otherwise specified) are considered to be carcinogenic defined with no further categorization by NIOSH and IARC. GHS labeling for units
Hazard pictograms
GHS07- GHS05 – GHS09
Contains
Zinc Chloride
Precautionary statements
P285 In case of inadequate ventilation wear respiratory protection. P314 Get medical advice/attention if you feel unwell. P280 Wear protective gloves/protective clothing/eye protection/face protection. P202 Do not handle until all safety precautions have been read and understood. P260 Do not breathe dust/fume/gas/mist/vapors/spray. P501 Dispose of contents/container to waste treatment facility in accordance with local and national regulations.
Hazard statements
H301 Toxic if swallowed. H302 Harmful if swallowed. H314 Causes severe skin burns and eye damage. H315 Causes skin irritation. H319 Causes serious eye irritation. H400 Very toxic to aquatic life. H410 Very toxic to aquatic life with long lasting effects. SECTION 2 NOTES: Before using this product, contact your doctor to determine if exposure to product or use of this product will aggravate your medical conditions. Spatter and flames from brazing and soldering may cause burns and start fires.