Note: Ingredients listed on restricted chemical lists
EC/CAS
7789-75-5
Name of the chemical
Calcium fluoride
Concentration
N/A
EC/CAS
14808-60-7
Name of the chemical
Silica, crystalline
Concentration
N/A
EC/CAS
7440-47-3
Name of the chemical
Chromium; chromic acid and its salts
Concentration
N/A
EC/CAS
232-188-7
Name of the chemical
Calcium fluoride
Concentration
N/A
EC/CAS
238-878-4
Name of the chemical
Quarz-A-Staub (s. u. TRGS 906)
Concentration
N/A
EC/CAS
231-157-5
Name of the chemical
Chromium; chromic acid and its salts
Concentration
N/A
EC/CAS
215-168-2
Name of the chemical
Iron Oxide Red
Concentration
N/A
General Information
Revision date
2021-05-13
Product name
Exaton 10SW
supplier name
ESAB AB
Emergency telephone
44-870-8200418 and 44-2038073798
Icons in SDS
Company Information
company name
ESAB AB
e-mail address of the competent person responsible for the Safety Data Sheet
sdsrequest@esab.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H372
Hazard statements
Code
Statements
H372
Causes damage to organs through prolonged or repeated exposure
Section 2
CLP CLASSIFICATION
Danger classes Specific Target Organ Toxicity — Repeated exposure, hazard category 1
Hazard statements
H372 H372 Causes damage to organs through prolonged or repeated exposure .
2.2 Label elements
Labelling according to Regulation (EC) No 1272/2008
Signal word
Danger
Precautionary statements
P314 Get medical advice/attention if you feel unwell. P270 Do no eat, drink or smoke when using this product. P264 Wash hands and face thoroughly after handling. P260 Do not breathe dust. P501 Dispose of contents/container to by lawful and appropriate disposal method.
Other hazards
This product contains quartz, normally not in an inhalable fraction. However dust from this flux both in inhalable and respirable fraction can cause silicosis and may cause cancer. Avoid eye contact or inhalation of dust from the product. Skin contact is normally no hazard but should be avoided to prevent possible allergic reactions. Persons with a pacemaker should not go near welding or cutting operations until they have consulted their doctor and obtained information from the manufacturer of the device. When this product is used in a welding process, the most important hazards are welding fumes, heat, radiation and electric shock. Fumes: Welding fumes are normally not a hazard with submerged arc welding, unless the arc burns through the flux bedding. Use enough flux to avoid burn-through. Overexposure to welding fumes may result in symptoms like metal fume fever, dizziness, nausea, dryness or irritation of the nose, throat or eyes. Chronic overexposure to welding fumes may affect pulmonary function. Overexposure to manganese and manganese compounds above safe exposure limits can cause irreversible damage to the central nervous system, including the brain, symptoms of which may include slurred speech, lethargy, tremor, muscular weakness, psychological disturbances and spastic gait. disturbances and spastic gait. Prolonged inhalation of chromium compounds above safe exposure limits can cause cancer. Heat: Spatter and melting metal can cause burn injuries and start fires. Radiation: Arc rays can severely damage eyes or skin. Electricity: ELECTRIC SHOCK can kill. Other Emergency Overview: Granules in varying colours. This product is normally not considered hazardous as shipped. Gloves should be worn when handling to prevent contaminating hands with product dust.