General Information

Product name

Ammonium persulfate solution

Product Synonyms

APS

CAS No.

7727-54-0

1.2.1 Relevant identified uses

SU24 Scientific research and development 15 minutes. Remove contact lenses, if present and easy to do. Get

Emergency telephone

Skin contact: Wash the areas of contact with water for at least 15

Icons in SDS

GHS05 GHS08

Company Information

company name

ES Laboratory, LLC

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H290, H315, H317, H319, H334

Hazard statements

Code

Statements

H290

May be corrosive to metals

Section 2

SECTION 2: Hazards identification

NFPA Rating Ingestion: Do not induce vomiting. Rinse mouth. Get medical aid immediately. Hazardous classification of the substance or mixture: Most important symptoms and effects, both acute and

Hazard categories

Category code delayed: Sensitization. Corrosive to metals 1 Recommendation for immediate medical care and special Skin corrosion/irritation 2 treatment needed, when necessary: No information. Serious eye damage/irritation 2 Respiratory sensitization 1 Section 5: Fire-Fighting Measures Skin sensitization 1

Signal word

Danger Extinguishing media: Water, dry chemical, foam, or carbon dioxide.

Hazard pictograms

Special hazards arising from the substance or mixture: Has a fire-promoting effect due to the release of oxygen. Fire may cause the evolution of sulfur oxides and nitrogen oxides. Special protective equipment or precautions for firefighters: Wear full protective clothing and self-contained respirator. Section 6: Accidental Release Measures Personal precautions, protective equipment, and emergency

Hazard statements

procedures: Wear protective equipment. Keep unprotected persons H290 May be corrosive to metals. away. Ensure adequate ventilation. H315 Causes skin irritation. Environmental precautions: Do not allow the material to be H317 May cause an allergic reaction. released to the environment without proper government permits. H319 Causes serious eye irritation. Methods and materials for containment and cleaning up: Use a H334 May cause allergy or asthma symptoms or neutralizing agent. Absorb with a liquid binding material (sand, breathing difficulties if inhaled. diatomite, acid binder, universal binders, sawdust). Dispose of

Precautionary statements

contaminated material as waste according to section 13. Ensure P280 Wear protective gloves/protective clothing/eye adequate ventilation. protection/face protection.

Response

Section 7: Handling and Storage P302+P352 IF ON SKIN: Wash with plenty of soap and water. Precautions for safe handling: Wear protective equipment. Ensure P304+P341 IF INHALED: If breathing is difficult, remove good ventilation at the workplace. Use under the hood. Avoid victim to fresh air and keep at rest in a inhalation of vapor or mist. position comfortable for breathing. Condition for safe storage: Keep container tightly sealed. Store in P305+P351+P338 IF IN EYES: Rinse cautiously with water for an approved corrosive liquid storage container/area. several minutes. Remove contact lenses, if Incompatibilities: Store away from organic and combustible present and easy to do. Continue rinsing. substances. P342+P311 If experiencing respiratory symptoms: call a Specific storage requirement(s): Store below 25 ˚C, away from POISON CENTRE or doctor/ physician. heat, direct sunlight. If possible, store in a refrigerator at 4 ˚C. If the

Storage

container starts to swell, twist and open the cap slowly to release the P405 Store locked up. oxygen gas build up. Inspect the content periodically. Dispose of

Disposal

content as a hazardous waste within six months of initial receipt. P501 Dispose of contents/container in accordance with local/regional/national/international Section 8: Exposure Controls/Personal Protection regulations.

2.3 Other hazards

No information Exposure Limits

2.2 Label elements

See tables above Component CAS No. ACGIH TLV OSHA PEL

NFPA Ratings

Ammonium 7727-54-0 0.1 mg/m3 TWA 0.1 mg/m3 Health: 2 persulfate Flammability: 0 Engineering controls: Use general and/or local exhaust ventilation Reactivity: 2 to control the vapor concentration. Special hazard: None Eye protection: Wear safety glasses or goggles. Skin protection: Wear protective clothing and chemical resistant

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.