Note: Ingredients listed on restricted chemical lists
EC/CAS
215-269-1/1317-38-0
Name of the chemical
Copper (II) oxide
Concentration
1-30
EC/CAS
231-159-6/7440-50-8
Name of the chemical
Copper
Concentration
1-30
EC/CAS
231-072-3/7429-90-5
Name of the chemical
Aluminium
Concentration
1-20
General Information
Version
US-EN/3.5
Revision date
2016-11-22
Product name
ERICO® CADWELD® Electrical Welding Material
1.2.1 Relevant identified uses
Exothermic Welding material
Manufacturer Name
PENTAIR
Emergency telephone
1-800-255-3924, +01-813-248-0585
Icons in SDS
Company Information
company name
ERICO International Corporation
e-mail address of the competent person responsible for the Safety Data Sheet
Amy.Lucia@Pentair.com
GHS Information
Signal word
WARNING
Hazard Codes
Hazard statements (CLP)
H302
Hazard statements
Code
Statements
H302
Harmful if swallowed
Section 2
SECTION 2: Hazards identification
OSHA Classification of the substance or mixture
2.2 Label elements
WARNING H302 Harmful if swallowed. P260 Do not breathe dust/fume P301 + P312 IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P273 Avoid release to the environment. P501 Dispose of contents/container in accordance with local regulations. P330 Rinse mouth. P264 Wash skin thoroughly after handling. P270 Do not eat, drink or smoke when using this product.
Other hazards
Other Improper use of the product or inadequate preparation of the conductors, molds or surroundings can result in aggressive reactions. Self-propagating high temperature reaction will occur if heated above ignition temperature. Generates molten metal in excess of 1370°C, slag and dense, dusty smoke. The molten product can cause serious burns. Inhalation of powder or fumes may cause metal fume fever. Exposure to reaction by-products: See section 8.
2.1 Classification of the substance or mixture
OSHA 2012: Acute Oral Toxicity Category 4