General Information
Revision date
2021-03-30
Product name
This ‘Product Safety Data Information’ Sheet covers Pall Medical 0.2, 0.8, 1.2 and 5.0 micron rated, disposable
CAS No.
32131-17-2
1.2.1 Relevant identified uses
The membrane filters detailed above are intended for air and gas filtration and separation applications – which do not soften, swell or adversely affect the filter, or its materials of construction
Emergency telephone
DATA INFORMATION
Icons in SDS
Company Information
company name
pall corporation
GHS Information
Signal word
No
Section 2
Product definition
Article. These products are not classified as hazardous according to REACH Regulation 1907/2006, or European CLP/GHS Regulation 1272/2008.
Signal word
No signal word.
Hazard statements
No known significant effects or critical hazards.
Special packaging requirements
None. ____________________________________________________________________________________ SECTION 3 - Materials of Construction The filters detailed in Section 1 are comprised of the following materials: Material Name CAS Number Acrylic copolymer membrane Pall proprietary information with hydrophobic surface modification Non-woven nylon 6,6 support material 32131-17-2 Modified acrylic copolymer housing body Polymer supplier proprietary information These products are not known to contain BADGE, NOGE, or BFDGE. Trace additives will be present in the plastic components. There are no additional ingredients present which, within the current knowledge of the supplier, are classified and contribute to the classification of the article. There are no current SVHC substances known to be present in the finished articles above 0.1%. There are no current ROHS2 Directive (2011/65/EU) and amendment (2015/863) substances of concern (including Lead, Cadmium, Mercury, Hexavalent Chromium, Polybrominated biphenyl (PBB), Polybrominated diphenyl ether (PBDE), Bis(2-ethylhexyl) phthalate (DEHP), Benzyl Butyl Phthalate (BBP), Dibutyl phthalate (DBP) and Diisobutyl phthalate (DIBP)) known to be present in the materials employed in excess of the limits laid down, based on information from our suppliers and knowledge of substances used within Pall the manufacturing facility. Pall Medical filters do not employ natural rubber latex, or latex derivatives in their construction. These products (see appendix 1) do not contain animal materials (i.e. animal parts, tissues, or body fluids). However, to assist our customers in performing a TSE/BSE risk assessment, we are pleased to provide the following information: Pall filters for healthcare and laboratory applications may utilise components which are fabricated from plastic resins containing animal-derived additives at trace levels such as tallow-derived substances. Please be advised that tallow-derived additives are not considered specified BSE risk materials according to the current revision of the U.S. Code of Federal Regulations, Title 21 of part 189.5. Furthermore, the CPMP's Note for guidance on minimising the risk of transmitting animal spongiform encephalopathies via human and veterinary medicinal products (EMA410/01 rev 3) gives specific consideration to tallow derivatives and state they are unlikely to be infectious due to the rigorous processing steps used during their manufacture (an example of which is transesterification, or hydrolysis, at not less than 200°C under pressure for not less than 20 minutes). These products are not known to contain perfluorooctanoic acid (PFOA), its salts and PFOA-related compounds at levels in excess of the limits given in European 2017/1000 amendment to the REACH requirements, which came into effect on July 4th 2020, and electrical and electronics industry standard IEC62474 (revision D18.00) of July 2019: PFOA and its salts 25ppb PFOA related compounds 1000ppb The above statement is based on a risk assessment approach considering: the supplier’s information on the key constituent in the ‘RC’ surface treatment concerning to PFOA, and Pall testing of the finished membrane for residual PFOA. Pall testing of the key constituent in the ‘RC’ surface treatment for PFOA related compounds was conducted. In addition, in May 2019 the Stockholm Convention moved to add perfluorooctanoic acid (PFOA) and/or PFOA-related compounds to its POPs Annex A with the intention of restricting the use of PFOA and its related compounds to a limited range of applications within the ratifying countries. There are no other current SVHC substances (including Bisphenol-A) known to be present in the finished articles above 0.1%. This product can expose you to PFOA which is known in the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov These products placed on the market in the State of California by Pall are not intended for ‘consumer’ sale, but, are for professional or industrial use. Therefore, the only anticipated exposure to these items would be through ‘occupational exposure’ which does not require mandatory labelling of all articles. In line with the ‘Questions and Answers for business’ (dated August 2017) on the labelling requirements – Q41 - this SDS conveys this warning for occupational exposure. ______________________________________________________________________________________