Note: Ingredients listed on restricted chemical lists
EC/CAS
123-86-4
Name of the chemical
acetic acid, butyl ester
Concentration
5 - 10
EC/CAS
108-10-1
Name of the chemical
4-methylpentan-2-one; isobutyl methyl ketone (MIBK)
Concentration
3.298
General Information
Version
1.3
Revision date
2024-07-18
Product name
DURACOAT CLEAR A
Emergency telephone
1-800-424-9300 24
Icons in SDS
Company Information
company name
Endura Manufacturing Company Ltd
e-mail address of the competent person responsible for the Safety Data Sheet
info@endura.ca
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H351
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
SECTION 2: Hazards identification
Classification (GHS-US)
Flammable liquids Category 2 Carcinogenicity Category 2 H225 Highly flammable liquid and vapor H351 Suspected of causing cancer
Hazard statements
see section 16 : H225 - Highly flammable liquid and vapor H351 - Suspected of causing cancer
2.2 Label elements
GHS US labeling
Hazard pictograms
GHS02 GHS08
Signal word
Danger
Precautionary statements
P201 - Obtain special instructions before use. P202 - Do not handle until all safety precautions have been read and understood. P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P233 - Keep container tightly closed. P240 - Ground/Bond container and receiving equipment. P241 - Use explosion-proof electrical/ventilating/lighting equipment P242 - Use only non-sparking tools. P243 - Take precautionary measures against static discharge. P280 - Wear protective gloves/protective clothing/eye protection/face protection. P303+P361+P353 - If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P308+P313 - If exposed or concerned: Get medical advice/attention. P370+P378 - In case of fire: Use dry chemical powder, alcohol-resistant foam, carbon dioxide (CO2) to extinguish P403+P235 - Store in a well-ventilated place. Keep cool. P405 - Store locked up. P501 - Dispose of contents/container in accordance with all local, regional, national and international regulations. 07/18/2024 EN (English US) Page 1