Note: Ingredients listed on restricted chemical lists
EC/CAS
67-56-1
Name of the chemical
Methanol
Concentration
>50
EC/CAS
7553-56-2
Name of the chemical
Iodine (I)
Concentration
<1
General Information
Revision date
2011-07-27
Product name
Aquastar Solvent
Product Synonyms
None
1.2.1 Relevant identified uses
Other non-specified industry: Analytical reagent
supplier name
EMD Chemicals Inc
Emergency telephone
800-424-9300
Icons in SDS
Company Information
company name
EMD Chemicals Inc
Section 2
SECTION 2: Hazards identification
OSHA Hazards Emergency overview : DANGER! POISON! FLAMMABLE LIQUID AND VAPOR. VAPOR MAY CAUSE FLASH FIRE. MAY BE FATAL OR CAUSE BLINDNESS IF SWALLOWED. CANNOT BE MADE NONPOISONOUS. VAPOR HARMFUL. HARMFUL IF INHALED OR ABSORBED THROUGH SKIN. CAUSES RESPIRATORY TRACT, EYE AND SKIN IRRITATION. CONTAINS MATERIAL WHICH MAY CAUSE DAMAGE TO THE FOLLOWING ORGANS: GASTROINTESTINAL TRACT, RESPIRATORY TRACT, SKIN, CENTRAL NERVOUS SYSTEM, EYE, LENS OR CORNEA. Keep away from heat, sparks and flame. Do not breathe vapor or mist. Do not ingest. Do not get in eyes or on skin or clothing. Use only with adequate ventilation. Keep container tightly closed and sealed until ready for use. Wash thoroughly after handling. Physical state : Liquid.
Potential Acute Health Effects
Inhalation : Toxic by inhalation. Irritating to respiratory system. Ingestion : May be fatal or cause blindness if swallowed. Skin : Toxic in contact with skin. Irritating to skin. Eyes : Irritating to eyes. Potential chronic health effects Carcinogenicity : No known significant effects or critical hazards. Mutagenicity : No known significant effects or critical hazards.
Teratogenic Effects
No known significant effects or critical hazards. Developmental effects : No known significant effects or critical hazards. Fertility effects : No known significant effects or critical hazards. Target organs : Contains material which may cause damage to the following organs: gastrointestinal tract, upper respiratory tract, skin, central nervous system (CNS), eye, lens or cornea. Medical conditions aggravated by over- : Pre-existing disorders involving any target organs mentioned in this MSDS as being at risk may be aggravated by over-exposure to this product. exposure See toxicological information (section 11)