Note: Ingredients listed on restricted chemical lists
EC/CAS
80-62-6
Name of the chemical
methacrylic acid, methyl ester
Concentration
N/A
EC/CAS
2082-81-7
Name of the chemical
methacrylic acid, diester with 1,4-butanediol
Concentration
N/A
General Information
Revision date
2019-09-10
Product name
LiteFix liquid
1.2.1 Relevant identified uses
Laboratory chemicals
Emergency telephone
1-800-424-9300 Contract CCN7661
Icons in SDS
Company Information
company name
Electron Microscopy Sciences
e-mail address of the competent person responsible for the Safety Data Sheet
sgkcck@aol.com
GHS Information
Signal word
Danger
Hazard Codes
Hazard statements (CLP)
H225, H315, H317, H335
Hazard statements
Code
Statements
H225
Highly Flammable liquid and vapour
Section 2
2.1 Classification of the substance or mixture
GHS02 Flame Flam. Liq. 2 H225 Highly flammable liquid and vapor. GHS07 Skin Irrit. 2 H315 Causes skin irritation. Skin Sens. 1 H317 May cause an allergic skin reaction. STOT SE 3 H335 May cause respiratory irritation.
2.2 Label elements
The product is classified and labeled according to the Globally Harmonized System (GHS)
Hazard pictograms
GHS02 GHS07
Signal word
Danger
Hazardous Ingredients
Methyl Methacrylate tetramethylene dimethacrylate
Hazard statements
Highly flammable liquid and vapor. Causes skin irritation. May cause an allergic skin reaction. May cause respiratory irritation.
Precautionary statements
Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Ground/bond container and receiving equipment. Use explosion-proof electrical/ventilating/lighting/equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing dust/fume/gas/mist/vapors/spray Wash thoroughly after handling. Use only outdoors or in a well-ventilated area. Contaminated work clothing must not be allowed out of the workplace. Wear protective gloves/protective clothing/eye protection/face protection. If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Call a poison center/doctor if you feel unwell. Specific treatment (see on this label). Take off contaminated clothing and wash it before reuse. If skin irritation or rash occurs: Get medical advice/attention. Wash contaminated clothing before reuse. In case of fire Use for extinction CO2, powder or water spray Store in a well-ventilated place. Keep container tightly closed. Store in a well-ventilated place. Keep cool. Store locked up. Dispose of contents/container in accordance with local/regional/national/international regulations.
Classification system
NFPA ratings (scale 0 - 4) Health = 1 3 Fire = 3 1 0 Reactivity = 0 · HMIS-ratings (scale 0 - 4) HEALTH 1 Health = 1 FIRE 3 Fire = 3 REACTIVITY 0 Reactivity = 0
PBT Substances
Not applicable
vPvB Substances
Not applicable