Note: Ingredients listed on restricted chemical lists
EC/CAS
1309-64-4
Name of the chemical
Diantimontrioxid
Concentration
10% 10-20%
EC/CAS
84852-53-9
Name of the chemical
1,1'-(ethane-1,2-diyl)bis[pentabromobenzene]
Concentration
10-20%
EC/CAS
3290-92-4
Name of the chemical
1,1,1-trimethylolpropane trimethacrylate
Concentration
0-3% 3-6%
General Information
Revision date
2017-05-17
Product name
903454-4 and 903454-5
Emergency telephone
1-203-723-2590 X336
Icons in SDS
Company Information
company name
Electric Cable Compounds, Inc
e-mail address of the competent person responsible for the Safety Data Sheet
wsmith@eccompounds.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H316, H317, H319, H332, H335, H351, H411
Hazard statements
Code
Statements
H316
Causes mild skin irritation
Section 2
2.1 Classification of the substance or mixture
Aquatic Chronic 2, H411 Acute Toxicity 4, H332 Carcinogen 2, H351 Skin Irritant 3, H316 Skin Sensitizer 1, H317 Eye Irritant 1, H319 Respiratory Irritant 3, H335
Hazard statements
H332 Harmful if inhaled. H351 Suspected of causing cancer. H411 Toxic to aquatic life with long lasting effects. H316 Causes mild skin irritation H335 May cause respiratory irritation H319 May cause serious eye irritation H317 May cause allergic skin reaction
Precautionary statements
P260 Do not breathe dust/fume/vapors. P314 Get medical advice/attention if you feel unwell. P273 Avoid release to the environment. P391 Collect spillage. P501 Dispose of contents/container in accordance with local regulations.
2.3 Other hazards
Dust may cause irritation of the eye and skin. Fumes from heating may irritate the respiratory system.