General Information
Version
6.a
Revision date
2020-07-01
Product name
Duracell Nickel Metal Hydride (NiMH) Rechargeable Batteries packaged with/in equipment
Product name
Duracell Nickel Metal Hydride (NiMH) Rechargeable Batteries packaged with/in equipment
Identification on the label/Trade name
Safety & Regulatory
supplier name
Safety & Regulatory
Icons in SDS
Company Information
company name
Duracell US Operations, Inc.
e-mail address of the competent person responsible for the Safety Data Sheet
asiaconsumer.im@duracell.com
Section 2
Precautionary statements
(For AAA & Smaller) “CAUTION: Keep batteries away from children. If swallowed, consult a physician at once. For information on treatment, call (202) 625‐3333 collect.” (All sizes)” CAUTION: Never use different battery brands, types, capacities, or systems at the same time. For proper insertion, please observe pole indications (+/‐). Duracell battery charger recommended. Keep batteries away from fire, or explosion may occur.” 6. Fire Hazard & Firefighting Fire Hazard Batteries may rupture or leak if involved in a fire. Extinguishing Media Use any extinguishing media appropriate for the surrounding area. Fires Involving Large Quantities of Large quantities of batteries involved in a fire will rupture and release caustic potassium hydroxide. Batteries Firefighters should wear self‐contained breathing apparatus and protective clothing. 7. Handling & Storage Handling Precautions Avoid mechanical and electrical abuse. Do not short circuit or install incorrectly. Batteries may rupture or vent if disassembled, crushed, recharged or exposed to high temperatures. Install batteries in accordance with equipment instructions.
Storage
Precautions Store batteries in a dry place at normal room temperature. Refrigeration does not make them last longer. Spills of Large Quantities of Loose Notify spill personnel of large spills. Irritating and flammable vapors may be released from leaking or Batteries (unpackaged) ruptured batteries. Spread batteries apart to stop shorting. Eliminate all ignition sources. Evacuate area and allow vapors to dissipate. Clean‐up personnel should wear appropriate PPE to avoid eye and skin contact and inhalation of vapors or fumes. Increase ventilation. Carefully collect batteries and place in appropriate container for disposal. Remove any spilled liquid with absorbent material and contain for disposal.
Disposal
Considerations (GHS Section 13) Collection & Proper Disposal Dispose of used (or excess) batteries in compliance with federal, state/provincial and local regulations. Do not accumulate large quantities of used batteries for disposal as accumulations could cause batteries to short‐circuit. Do not incinerate. In countries, such as Canada and the EU, where there are regulations for the collection and recycling of batteries, consumers should dispose of their used batteries into the collection network at municipal depots and retailers. They should not dispose of batteries with household trash. USA EPA RCRA (40 CFR 261) Nickel metal hydride rechargeable batteries are considered RCRA Universal Waste as long as they are recycled. In some states (California, New York, Minnesota, and Maine) Nickel metal hydride batteries must be recycled by state law. California Universal Waste Rule (Cal. California prohibits disposal of batteries as trash (including household trash). Code Regs. Title 22, Div. 4.5, Ch. 23) 9. Transport Information (GHS Section 14) Regulatory Status Nickel metal hydride (NiMH) batteries are not defined as dangerous goods under IATA, ICAO, and DOT. NIMH batteries packed in/with battery chargers are not regulated. NIMH batteries packed in/with battery chargers,devices, or equipment are not regulated. NIMH batteries, not shipped with/in devices or chargers, are defined as UN3496 dangerous goods under IMDG code for sea transportation with Special Provision (SP) SP177 and SP963 applicable. SP963 States: •Nickel‐metal hydride cells or baeries packed with or contained in equipment are not subject to the provisions of the IMDG Code. •All other nickel‐metal hydride cells or baeries shall be securely packed and protected from short circuit. They are not subject to other provisions of this Code provided that they are loaded in a cargo transport unit in a total quantity of less than 100 Kg gross mass. When loaded in a cargo transport unit in a total quantity of 100 Kg gross mass or more, they are not subject to other provisions of this Code except those of 5.4.1, 5.4.3 and column (16) of the dangerous good list in Chapter 3.2. •The requirements of the 5.4.1 & 5.4.3 secons and column (16) are: dangerous goods transport documentation to accompany the shipment, the shipment must be described as "UN3496, BATTERIES, NICKEL‐METAL HYDRIDE, CLASS 9" on the shipper's declaration for dangerous goods. The dangerous goods description must also be entered on the Dangerous Cargo Manifest and/or the detailed stowage plan in compliance with the IMDG Code requirements for shipboard documentation. Stowage away from sources of heat. SP117 States: SP117 States: NIMH cells and batteries are only regulated when transported by sea. UN Identification Number/ UN3496 ‐ Batteries, Nickel Metal Hydride Shipping Name
Special Provisions
(SP) Conformance Special regulatory provisions require batteries to be packaged in a manner that prevents the generation of a dangerous quantity of heat and short circuits. Shippers can prepare batteries by taping the terminals, individually packaging batteries, or otherwise segregating the batteries to prevent risk of creating a short circuit. Batteries shipped in original unopened Duracell packaging is compliant. Internation Maritme Dangerous CODE: UN‐3496, SP‐117 & SP‐963 [2018 EDITION] Goods (IMDG) US DOT SP 49 CFR 172.102 Special Provisions 130 and 340 Air Transport (IATA/ICAO) SP A199 (IATA 61th Edition ‐ 2020). NOTE The words "NOT RESTRICTED" and A199" must be included on the description of the substance on the Air Waybill, when air way‐bill is issued. Passenger Air Travel No restrictions Emergency Transportation Hotline CHEMTREC 24‐Hour Emergency Response Hotline Within the United States call +703‐527‐3887 Outside the United States, call +1 703‐527‐3887 (Collect) 10. Regulatory Information (GHS Section 15) 10a. Battery Requirements USA EPA Mercury Containing & During the manufacturing process, no mercury is added. Rechargeable Battery Management Act of 1996 EU Battery Directive 2006/66/EC Compliant with marking and substance restrictions for mercury (<0.0005%); cadmium (<0.0020%)l & amendment 2013/56/EU and lead (<0.0040%). Global labels are marked with the special collection symbol and the EU qualifier in accordance with EU Battery Directive 2006/66/EC, Article 11, Paragraph 1 on batteries and accumulators and waste batteries and accumulators (Annex II). 10b. General Requirements USA CPSIA 2008 (PL. 11900314) Exempt USA CPSC FHSA (16 CFR 1500) Consumer batteries are not listed as a hazardous product. USA EPA TSCA Section 13 (40 CFR For customs clearance purpose, batteries are defined as an "Article". 707.20) USA EPA RCRA (40 CFR 261) Nickel metal hydride rechargeable batteries are considered RCRA Universal Waste as long as they are recycled. In some states (California, New York, Minnesota, and Maine) Nickel metal hydride batteries must be recycled by state law. California Prop 65 No warning required per 3rd party assessment. CANADA Products Containing Mercury free Mercury Regulations SOR/20140254 EU REACH REGULATION (EC) NO. Regulated as an “article.” No listed substances are present (>0.1% w/w) in accordance with ECJ
Further information
AIS Hazard Communication Approaches (consulted in developing this document): Globally Harmonized System (GHS) GHS SDS requirements and classification criteria do not apply to articles or products (such as batteries) that have a fixed shape, which are not intended to release a chemical. The article exemption is found in Section 1.3.2.1.1 of the GHS and reads: The GHS applies to pure substances and their dilute solutions and to mixtures. "Articles" as defined by the Hazard Communication