Note: Ingredients listed on restricted chemical lists
EC/CAS
212-377-0/811-97-2
Name of the chemical
1,1,1,2-Tetrafluoroethane
Concentration
100%
General Information
Version
6.1
Revision date
2011-07-15
Product name
DuPont SUVA 134a refrigerant ASHRAE Refrigerant number designation R-134a
Product Synonyms
1,1,1,2-Tetrafluoroethane HFC-134a
CAS No.
811-97-2
REACH No
01-2119459374-33-0002
1.2.1 Relevant identified uses
Refrigerant
Emergency telephone
+44-(0)8456-006.640
Icons in SDS
Company Information
company name
Du Pont de Nemours (Nederland) B.V
e-mail address of the competent person responsible for the Safety Data Sheet
sds-support@che.dupont.com
GHS Information
Signal word
Warning
Hazard Codes
Hazard statements (CLP)
H280
Hazard statements
Code
Statements
H280
Contains gas under pressure; may explode if heated
Section 2
SECTION 2: Hazards identification
1999/45/EC Classification of the substance or mixture Gases under pressure, H280: Contains gas under pressure; may explode if heated Liquefied gas
2.2 Label elements
Gas cylinder Warning H280 Contains gas under pressure; may explode if heated. Special labelling of certain
Contains
1,1,1,2-Tetrafluoroethane / Contains fluorinated greenhouse gas substances and mixtures covered by the Kyoto Protocol. P410 + P403 Protect from sunlight. Store in a well-ventilated place.
2.3 Other hazards
This substance is not considered to be persistent, bioaccumulating nor toxic (PBT). This substance is not considered to be very persistent nor very bioaccumulating (vPvB). Rapid evaporation of the liquid may cause frostbite. Vapours are heavier than air and can cause suffocation by reducing oxygen available for breathing. May cause cardiac arrhythmia.
2.1 Classification of the substance or mixture
H280: Contains gas under pressure; may explode if heated. Liquefied gas Not a hazardous substance or mixture according to EC-directives 67/548/EEC or 1999/45/EC. Label elements