202V Vana-Stop New Masonry Cleanerunborn child

310 Wayto Road

Revision date : 2015-03-01

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.
GHS06 GHS08
Health risk rating 5
Safety risk rating 1
Environmental risk rating 1

Note: Ingredients listed on restricted chemical lists

EC/CAS

7647-01-0

Name of the chemical

Hydrochloric acid

Concentration

2 ppm

EC/CAS

7664-93-9

Name of the chemical

sulphuric acid

Concentration

N/A

General Information

Revision date

2015-03-01

Product name

202V Vana-Stop New Masonry Cleanerunborn child

1.2.1 Relevant identified uses

Household use P264 Wash skin thoroughly after handling P271 Use only outdoors or in a well-ventilated area

Manufacturer Name

Diedrich Technologies, A Hohmann & Barnard

Emergency telephone

800-424-9300

Icons in SDS

GHS06 GHS08 M004 M009 M010 M011 M017

Company Information

company name

310 Wayto Road

e-mail address of the competent person responsible for the Safety Data Sheet

moreinfo@sandellmfg.com

GHS Information

Signal word

Danger

Hazard Codes

Hazard statements (CLP)

H303, H314, H318, H330, H334

Hazard statements

Code

Statements

H303

May be harmful if swallowed

Section 2

SECTION 2: Hazards identification

Classifications

protection/face protection P281 oral toxicity: Acute Tox. 5 P284 Use personal protective equipment as required Wear respiratory protection Anticipated oral LD50 between 2000 and 5000 mg/kg; P285 Indication of significant effect in humans; Any mortality at In case of inadequate ventilation wear respiratory protection class 4; Significant clinical signs at class 4 P310 Immediately call a POISON CENTER Inhalation toxicity Acute Tox. 1 or doctor/physician Gases <=100ppm, Vapors <=0.5mg/l, Dusts & mists P312 Call a POISON CENTER or doctor/physician <=0.05mg/l if you feel unwell P320 Specific treatment is urgent (see section 4) skin corrosive 1A P321 Specific treatment (see section 4) Destruction of dermal tissue Exposure < 3 min. Observation <1 hour, visible necrosis in at least one animal P363 Wash contaminated clothing before reuse P301+P330+P331 Eye corrosive 1 IF SWALLOWED Rinse mouth. Do NOT Serious eye damage Irreversible damage 21 days after induce vomiting exposure, Draize score Corneal opacity >= 3, Iritis > 1.5 P303+P361+P353 respiratory sensitizer 1 IF ON SKIN (or hair) Remove/Take off immediately all contaminated clothing. Rinse skin with water/ carcinogen 1B shower Presumed Human Carcinogen, Based on demonstrated P304+P340 animal carcinogenicity IF INHALED Remove victim to fresh air and keep reproductive toxin 2 at rest in a position comfortable for breathing Human or animal evidence possibly with other information P304+P341 IF INHALED: If breathing is difficult, remove

Hazard statements

victim to fresh air and keep at rest in a position H303 May be harmful if swallowed comfortable for breathing H314 Causes severe skin burns and eye damage P305+P351+P338 H318 Causes serious eye damage IF IN EYES: Rinse continuously with water H330 Fatal if inhaled for several minutes. Remove contact lenses if H334 May cause allergy or asthma symptoms or present and easy to do – continue rinsing breathing difficulties if inhaled P308+P313 5. fIrE fIGHtING MEasurEs IF exposed or concerned Get medical advice/ flammable limits LEL & UEL – N/A attention flash Point No data available P342+P311 Extinguishing Media: Use extinguishing agent suitable for Call a POISON CENTER or doctor/physician type of surrounding fire. P405 Store locked up unusual fire or Explosion Hazards No data available. P403+P233 Store in a well ventilated place. Keep container Hazardous combustion Products See Section 10 for a tightly closed list of hazardous decomposition products for this mixture. P501 Dispose of contents/container according to fire fighting If evacuation of personnel is necessary, local regulations evacuate to an upwind area. Decontaminate personnel and equipment with a water wash-down after fire and smoke danger exposure. fire fighting Fire fighters should wear complete protective clothing including self-contained breathing apparatus. 6. accIdENtal rElEasE MEasurEs Isolate the area and contain the spilled material. Persons not wearing the appropriate PPE should be removed from the area

SDS Library

Move your SDS library online today

Check Icon
Setup – Easy setup with our database of 16 million+ SDSs
Check Icon
Up-to-date – Your SDS get updated to latest versions.
Check Icon
Employee access – Tablets, Smartphones, or link from Corporate Intranet
Check Icon
Safety – One-click access to first aid information.
Check Icon
Labels – Generate Secondary Container Labels with just one click.