Note: Ingredients listed on restricted chemical lists
General Information
Revision date
2020-04-15
Product name
DEWALT TRAK-IT FUEL CELL
Chemical name
Mixture of: Hydrocarbon gases
supplier name
DEWALT Industrial Tool Co
Manufacturer Name
DEWALT Industrial Tool Co
Emergency telephone
1-800-424-9300, 703-527-3887
Icons in SDS
Company Information
company name
DEWALT Industrial Tool Co
GHS Information
Signal word
DANGER!
Hazard Codes
Hazard statements (CLP)
H220, H280
Hazard statements
Code
Statements
H220
Extremely flammable gas
Section 2
SECTION 2: Hazards identification
(29 CFR 1910.1200) Classification of the chemical Liquified gas. Colorless. Mild olefinic odor Most important hazards:Extremely flammable gas May be ignited by open flames and sparks. May displace oxygen and cause rapid suffocation
Signal word
DANGER!
Hazard statements
Extremely flammable gas Contains gas under pressure; may explode if heated. May displace oxygen and cause rapid suffocation
Precautionary statements
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources - No smoking. Leaking gas fire: do not extinguish, unless leak can be stopped safely. Eliminate ignition sources if safe to do so. Store in a well-ventilated place. Protect from sunlight.
Other hazards which do not result in classification
None reported by the manufacturer
2.1 Classification of the substance or mixture
Liquified gas. Colorless. Mild olefinic odor. Most important hazards:Extremely flammable gas May be ignited by open flames and sparks. May displace oxygen and cause rapid suffocation. This material is classified as hazardous under U.S. OSHA regulations (29CFR 1910.1200) (Hazcom 2012) and Canadian WHMIS regulations (Hazardous Products Regulations) (WHMIS 2015). Hazard classification Flammable gas - Category 1 Gases under pressure -Liquefied gas Simple asphyxiant